background image

2 of 8

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C4XRO-E

Technical Data Sheet

Engineering

Plan Views

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

3

/

(120)

Splashguard

A

41 

1

/

(1054)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Waste Outlet

Waste Outlet

FRONT

8

 

(203)

1

/

(115)

12 

1

/

(307)

43 

7

/

(1114)

C

Wireway

3

/

(120)

26 

1

/

(673)

1

/

(108)

Electrical 
Field 
Connection

46 

1

/

(1174)

48

 

(1220)

40 

5

/

(1032)

56 

1

/

(1435)

44 

5

/

(1133)

B

D

41 

1

/

(1054)

38 

1

/

(978)

Convertible

10-2005

C4XRO

Dimensions shown as inches and (mm).

4 ft

6 ft

8 ft

10 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

120 

3

/

8

(3058)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

56 

1

/

(1435)

56 

1

/

(1435)

56 

1

/

(1435)

56 

1

/

(1435)

56 

1

/

(1435)

Back of case to front of splashguard

48 (1220)

48 (1220)

48 (1220)

48 (1220)

48 (1220)

Back of case to O/S edge of front leg

44 

5

/

(1133)

44 

5

/

(1133)

44 

5

/

(1133)

44 

5

/

(1133)

44 

5

/

(1133)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

29 

1

/

(750)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

108 

1

/

(2750)

132 

3

/

(3363)

Back of case to center of stub up area

38

1

/

2

(978)

38

1

/

2

(978)

38

1

/

2

(978)

38

1

/

2

(978)

38

1

/

2

(978)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

114 

1

/

(2092)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

108 

1

/

(2750)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

46 

1

/

(1174)

46 

1

/

(1174)

46 

1

/

(1174)

46 

1

/

(1174)

46 

1

/

(1174)

Schedule 40 PVC drip pipe

1

/

4

(32)

1

/

4

(32)

1

/

4

(32)

1

/

4

(32)

1

/

4

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

40 

5

/

(1032)

40 

5

/

(1032)

40 

5

/

(1032)

40 

5

/

(1032)

40 

5

/

(1032)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

8  (203)

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Summary of Contents for C4XRO-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 10 Ft uses...

Page 2: ...054 29 1 2 750 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Se...

Page 3: ...entional UNLIT 1540 1640 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA C4XRO E Frequency Hrs 6 Defrost Water lb ft day 8 15 based on...

Page 4: ...0Hz Energy Efficient 0 50 0 60 0 80 1 30 1 10 Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 2...

Page 5: ...t 0 90 m3 m ARI Total Display Area 3 Sq Ft Ft 4 18 ft2 ft 1 27 m2 m Shelf Area 4 Sq Ft Ft 9 27 ft2 ft 2 83 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length...

Page 6: ...Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: