background image

P/N 0475447_C

3 of 8

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

3

/

(222)

Refrigeration 

Outlet

Electrical 

Case to Case 

Connections

C4XRO-E

FAN


L

3 In. 

(77 mm) 

Required 

Air Gap

81 

3

/

4

 

(2077)

11 

7

/

8

 

(302)

46 

1

/

(1174)

3

/

4  

(120)

48

 

(1220)

28 

5

/

8

 

(727)

12  

1

/

(311)

23 

3

/

4

 

(603)

40 

5

/

(1032)

44 

3

/

4

 

(1136)

52 

7

/

8

 

 

(1343)

11

 

(280)

56 

1

/

(1435)

45

 

(1143)

31

 

(788)

42

 

(1067)

31 

3

/

(806)

44 

5

/

(1133)

14 

3

/

8

 

(365)

1

/

4

 

(183)

Impact  

Excel

C4XRO-E

Produce Only

Multi-deck, 4 Display Levels

Dimensions shown as inches and (mm).

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

C4XRO-E

Produce

Discharge Air (°F)

31

Evaporator (°F)

24

Unit Sizing (°F) 

22

Btu/hr/ft — Unlit Shelves

C4XRO-E

‡‡

Parallel

Conventional

U

NLIT

1540

1640

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

C4XRO-E

Frequency Hrs

6

Defrost Water (lb/ft/day)

8

(± 15% based on case configuration and product

loading).

O

FFTIME

C4XRO-E

Temp Term °F

48

Failsafe Minutes

30

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

C4XRO-E

Produce 

17°F / 7°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to determine

PSIG conversions.

Estimated Charge (lb)**

C4XRO-E

4 ft

1.6

6 ft

2.3

8 ft

3.2

10 ft

3.8

12 ft

4.5

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Summary of Contents for C4XRO-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 10 Ft uses...

Page 2: ...054 29 1 2 750 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Se...

Page 3: ...entional UNLIT 1540 1640 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA C4XRO E Frequency Hrs 6 Defrost Water lb ft day 8 15 based on...

Page 4: ...0Hz Energy Efficient 0 50 0 60 0 80 1 30 1 10 Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 2...

Page 5: ...t 0 90 m3 m ARI Total Display Area 3 Sq Ft Ft 4 18 ft2 ft 1 27 m2 m Shelf Area 4 Sq Ft Ft 9 27 ft2 ft 2 83 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length...

Page 6: ...Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: