IGIC-CIDM-0508
4
SAFeTY STAnDARD: in compliance with the european laws.
Installation precautions
• the connection cables should be suitable for up to 195°F operation;
Caution: Low voltage and probe wiring must be properly separated from high voltage wiring
DISpLAY
During normal working conditions, the display shows the value measured by the air regulation probe or by the second
probe (parameter /4). In case of active alarm, the temperature flashes alternatively to the code alarm.
ALARMS AnD SIGnALS
Alarm code
Description
E0
fault air regulation probe
E1
evaporator product/food probe fault digital input alarm
IA
immediate external alarm (A4 and A7 parameters)
LO
low temperature alarm (AL, Ad and A0 parameters)
HI
high temperature alarm (AH, Ad and A0 parameters)
EE
data acquisition failure (see the manual for the default procedure)
Ed
timeout-ended defrost (dt, dP and r3 parameters)
dF
defrost in progress
OpeRATInG InSTRUCTIOnS On THe DISpLAY
•
LED Button
indicates compressor ON;
•
LED Button
indicates defrosting ON;
•
LED Button indicates presence of alarms.
The blinking indicates that controller is waiting for a time delay to expire.
SeT pOInT (desired temperature value)
• Press the SET
button for one second to display the Set-Point value;
• After few seconds, the set value blinks;
• Press UP
or DOWN
to increase or decrease the set-point value; press the
button once/more to
confirm the new value.
MAnUAL DeFROST
Besides the automatic defrost; it is possible to activate a manual defrost by pressing the
button for more than 5
seconds (it occurs only in the appropriate temperature conditions).
ACCeSS AnD MODIFICATIOn OF THe FReQUenT pARAMeTeRS (F TYpe)
1) Press the
button for more than 5 seconds (in case of alarm, first silence the buzzer);
) the display displays PS;
3) Press
or
to show the parameter whose value has to be changed; press
to display the associated value;
4) Press
or
to change the value;
5) Press
to temporarily confirm the new value and go back to display the parameter code; In order to modify the
other parameters, start back from point 3.
Storage of the new values:
press
at least for 5 seconds to store the new value and exit the "PARAMETERS
MODIFICATION" procedure. For timing parameters only: switch off and switch on the controller in order to make them
immediately effective without waiting for the following cycle.
To exit without modifying any parameter:
do not press
any button for at least 60 seconds (TIME OUT).