User Information

Stocking

Improper  temperature  and  lighting  will  cause  serious 

product  loss.  Discoloration,  dehydration  and  spoilage 

can be controlled with proper use of the equipment and 

handling of product. Product temperature should always 

be  maintained  at  a  constant  and  proper  temperature. 

This  means  that  from  the  time  the  product  is  received, 

through storage, preparation and display, the temperature 

of the product must be controlled to maximize life of the 

product. Hussmann cases were not designed to “heat up” 

or “cool down” product - but rather to maintain an item’s 

proper temperature for maximum shelf life. To achieve the 

protection required always:

1.   Minimize processing time to avoid damaging 

temperature rise to the product. Product should be at 

proper temperature.

.   Keep the air in and around the case area free 

of foreign gasses and fumes or food will rapidly 

deteriorate.

3.   Maintain the display merchandisers temperature 

controls as outlined in the refrigerator section of this 

manual.

4.   Do not place any product into these refrigerators 

until all controls have been adjusted and they 

are operating at the proper temperature. Allow 

merchandiser to operate a minimum of 6 hours 

before stocking with any product.

5.   When stocking, never allow the product to extend 

beyond the recommended load limit. 

Air discharge 

and return air flow must be unobstructed at all 

times to provide proper refrigeration.

6.   Avoid the use of supplemental flood or spot lighting.  

Display light intensity has been designed for 

maximum visibility and product life at the factory. 

The use of higher output fluorescent lamps (H.O.and 

V.H.O.),will shorten the shelf life of the product.

Case Cleaning

Long life and satisfactory performance of any equipment 

are  dependent  upon  the  care  given  to  it. To  insure  long 

life,  proper  sanitation  and  minimum  maintenance  costs, 

the  refrigerator  should  be  thoroughly  cleaned  frequently. 

SHUT OFF FAN DURING CLEANING PROCESS. It can be 

unplugged within the case, or shut off case at the source. 

The interior bottom may be cleaned with any domestic soap 

or detergent based cleaners. Sanitizing solutions will not 

harm the interior bottom, however, these solutions should 

always be used according to the manufacturer’s directions. It 

is essential to establish and regulate cleaning procedures.
This  will  minimize  bacteria  causing  discoloration  which 

leads  to  degraded  product  appearance  and  significantly 

shortening product shelf life.

Soap and hot water are not enough to kill this bacteria. A 

sanitizing  solution  must  be  included  with  each  cleaning 

process to eliminate this bacteria.

1.   Scrub thoroughly, cleaning all surfaces, with soap 

and hot water.

2.   Rinse with hot water, but do not flood.

3.   Apply the sanitizing solution according to the 

manufacturer’s directions.

4.   Rinse thoroughly.

5.   Dry completely before resuming operation.

Cleaning Glass and Mirrors

Only use a soft cloth and mild glass cleaner for cleaning 

any glass or mirrored components. Be sure to rinse and/or 

dry completely.

never  use  hot  water  on  cold  glass  surfaces!  It  may 

shatter and cause serious injury!

 Allow glass surfaces 

to warm first.

Finishing Touches (Cont'd)

4.  Apply cement with applicator to one or both 

surfaces. Join immediately.

5.   Apply just enough pressure to remove any air 

bubbles. Do not squeeze joint so hard as to force 

cement out of the joint - A dry joint may result.

6.   Allow approximately 4 hours to dry (at 70° F).

Acrylic Cement

Plastic Rod

Masking Tape

Summary of Contents for CHINO CIDM-E

Page 1: ...CIDM E CIDM I p n IGIC CIDM 0508 INSTALLATION OPERATION GUIDE CHINO CIDM E I Rev 0508 Installation Operation Manual...

Page 2: ...ains Information on CIDME CIDMI Refrigerated Self Service Island Display including 4 Crown and 3 Center Modules available as standard refrigerated med temp Shipping Damage All equipment should be thor...

Page 3: ...Plan Views 29 1 2 6 9 19 5 16 6 3 16 2 7 8 11 3 11 16 40 13 16 48 3 16 CIDM ISLAND 3 11 16 CIDME 34 7 8 3 1 16 12 13 16 27 36 33 30 3 8 10 Elec Elec Elec Ref 26 1 8 25 1 8 23 1 16 21 1 8 23 1 8 Ref D...

Page 4: ...hen cases are joined in the field When joining use a carpenters level and shim legs accordingly Case must be raised correctly under legs where support is best to prevent damage to case 1 Check level o...

Page 5: ...and product losses Please follow the recommendations listed below when installing condensate drains to insure a proper installation 1 Never use pipe for condensate drains smaller than the nominal dia...

Page 6: ...Access to TX Valves and Drain Lines Mechanical Remove product from end of case Remove product racks Remove refrigeration and drain access panels labeled TX valve mechanical only and drain are located...

Page 7: ...s provided on the exterior back of these models is intended for computerized scales with a five amp maximum load not for large motors or other high wattage Finishing Touches Plexiglass Joining Instruc...

Page 8: ...V H O will shorten the shelf life of the product Case Cleaning Long life and satisfactory performance of any equipment are dependent upon the care given to it To insure long life proper sanitation an...

Page 9: ...ocated on the case itself CLEANING PRECAUTIONS When cleaning Do not use high pressure water hoses Do not introduce water faster than waste outlet can drain NEVER ONASELF CONTAINED UNIT WITHAN EVAPORAT...

Page 10: ...DM CIDME 4 X3 W0300006 CIDME w OMNISTAT W0300008 CIDMI 3 W0300007 CIDMI 3 w OMNISTAT W0300009 CIDM I R 14 W0300017 CIDM I SC 14 W0300018 CIDM I R Hot Gas 14 W0300019 CIDM I R Hot Gas 10 W0300020 CIDM...

Page 11: ...FAN H4 H2 H3 H1 L2 ZONE SENSOR IS LOCATED BEHIND THE TOP FRONT DISCHARGE AND IS ATTACHED TO THE FRONT CAD SUPPORT STANDARD EVAP SENSOR IS LOCATED ON THE SECOND RUN OF THE COIL COMING AWAY FROM THE CAD...

Page 12: ...OMNI STAT PN952911 230VAC POWER SUPPLY 230 Vac PROD TEMP AIR TEMP L 9 1 2 3 4 5 6 7 8 CONDENSING UNITS COPELAND F9AM A103 CFV 140 1 H P R 22 RLA 9 5 1857W MCC 13 7 LRA 43 3 225 03 0121 1 R CONDENSING...

Page 13: ...T8 SPX30 2 125 03 1072 F25 T8 SPX30 2 125 03 1072 208 240 VAC 60 Hz L1 ZONE EVAP DEF COMM COMP ALARM FAN H4 H2 H3 H1 L2 ZONE SENSOR IS LOCATED BEHIND THE TOP FRONT DISCHARGE AND IS ATTACHED TO THE FRO...

Page 14: ...MCC 13 7 LRA 43 3 225 03 0121 1 R CONDENSING UNIT M M LIGHT CIRCUIT 93A 100W M CRTL PRSR DUAL 225 01 0706B BLK 14 RED 14 WHT 14 WHT 14 RED 14 BLK 14 RED 14 MCA 7 8A MOP 15A SAFETY SWITCH FLOAT SWITCH...

Page 15: ...2 F25 T8 SPX30 2 125 03 1072 F25 T8 SPX30 2 125 03 1072 F25 T8 SPX30 2 125 03 1072 M M M EVAP FAN MOTORS 2 9W CW 125 01 3076 TERMINAL BLOCK 125 01 0295 BLUE WHITE 115 V L1 2 6 L2 L3 208 V 17 5 17 5 24...

Page 16: ...W BROWN BROWN CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE WHITE BLACK BROWN BROWN BROWN BROWN YELLOW YELLOW RED RED BLUE WHITE BLUE WHITE BLUE BLUE BALLAST 125 01 3273 MAGNETE B432PUNVHP A BAL...

Page 17: ...B432PUNVHP A BLUE BLUE BLUE WHITE BLUE WHITE RED RED YELLOW YELLOW BROWN BROWN BROWN BROWN BLACK WHITE F15 T8 SPX30 2 125 03 0007 F15 T8 SPX30 2 125 03 0007 F15 T8 SPX30 2 125 03 0007 F15 T8 SPX30 2 1...

Page 18: ...W BROWN BROWN CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE WHITE BLACK BROWN BROWN BROWN BROWN YELLOW YELLOW RED RED BLUE WHITE BLUE WHITE BLUE BLUE BALLAST 125 01 3273 MAGNETE B432PUNVHP A BAL...

Page 19: ...F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F32T8 48 125 03 1073 F32T8 48 1...

Page 20: ...5 03 1073 M M M 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 BLACK WHITE M FAN MOTORS 4 9W CW 00001212 F15T8 18 125 03 1075 F15T8 18 125 03 1075 F15T...

Page 21: ...18 07 CIDM W0300021 CIDM E R EVAP FAN MOTORS 2 125 01 0615A 6A 49W 120VAC LIGHT SWITCH TOGGLE 125 01 0307 INSIDE PERIMETER LIGHTS 2 125 03 1075 F15 T8 SPX30 OUTSIDE PERIMETER LIGHTS 4 125 03 1071 F17...

Page 22: ...MCA 65A MOP 15A L1 N BLK 14 WHT 14 TAG ORANGE BLK 14 WHT 14 TAG BROWN BALLAST 125 01 3266 FULHAM LH3 120 L INCOMING POWER 120 VAC 60 Hz GFCI DUPLEX 125 01 3178 BLK NOTE FOR GFCI PROTECTION IF MORE THA...

Page 23: ...t after control Switch On or from digital input A4 or A5 4 C 0 199 min 0 0 d6 Block temperature display during defrost 0 no 1 yes C 0 1 flag 1 1 dd Dripping time after defrost F 0 15 min 2 0 d8 Alarm...

Page 24: ...POINT desired temperature value Press the SET button for one second to display the Set Point value After few seconds the set value blinks Press UP or DOWN to increase or decrease the set point value p...

Page 25: ...with normal refrigeration practices Refrigeration piping should be insulated according to Hussmann s recommendations 1 3 A clogged waste outlet blocks refrigeration The installer is responsible for th...

Page 26: ...arge opening c READING It should first be determined that the refrigerator is refrigerating and has operated at least one hour since the end of the last defrost period The thermometer reading should b...

Page 27: ...hese rules a Buy quality products b Receive perishables from transit equipment at the ideal temperature for the particular product c Expedite perishables to the store s storage equipment to avoid unne...

Page 28: ...________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________...

Reviews: