Rev.0210
11
Electrical and Refrigeration Specifications
TEMPERATURE
DISCHG.
FAN SIZE
DEFROST
ELECTRICAL CIRCUITS
SELF CONTAINED UNIT DATA
BTU
AVG
AIR
T-STAT/
TYPE
&
FREQ.
115 V.
SELF CONTAINED
REQ’D
EVAP
PROD
DISC
VELOC
CUT IN
OF
NUMBER
&
E E FANS
STD.
LOW PRESSURE
LENGTH
PER FT.
TMP
TMP
TMP
@FPM
SETTINGS
COIL
OF MOTORS
DURATION
(OPT.)
FANS
CONTROL & SETTINGS
H.P.
VOLTS
AMPACITY
DBRP-01
Crown
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.98
3.6
100
Air
(6)
(2)
1 point
No loads - Connection point only
2 point
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.98
3.6
100
Air
(6)
(3)
3 point
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
2.31
4.2
100
Air
(7)
(3)
8'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
.66
1.2
100
Air
(2)
(2)
10'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
.99
1.8
100
Air
(3)
(2)
12'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.32
2.4
100
Air
(4)
(2)
14'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.65
3.0
100
Air
(5)
(2)
DBRP-01 Octagon
Crown
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
2.64
4.8
100
Air
(8)
(2)
DBRP-03
8'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
.66
1.2
30# Out
1
208/
13.0
100
Air
(2)
(3)
50# In
230
10'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
.99
1.8
30# Out
1
208/
13.0
100
Air
(3)
(3)
50# In
230
12'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.32
2.4
30# Out
1
1
/2
208/
19.0
100
Air
(4)
(3)
50# In
230
-
14'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.65
3.0
30# Out
1
1
/2
208/
19.0
100
Air
(5)
(3)
50# In
230
-
16'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
1.98
3.6
30# Out
2
208/
21.4
100
Air
(6)
(3)
50# In
230
-
18'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
2.31
4.2
30# Out
2
208/
21.4
100
Air
(7)
(3)
50# In
230
-
20'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
2.64
4.8
30# Out
3
208/
35.7
100
Air
(8)
(3)
50# In
230
22'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
2.97
5.4
30# Out
3
208/
35.7
100
Air
(9)
(3)
50# In
230
24'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
3.3
6.0
30# Out
3
208/
35.7
100
Air
(10)
(3)
50# In
230
26'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
3.63
6.6
30# Out
3
208/
35.7
100
Air
(11)
(3)
50# In
230
28'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
3.96
7.2
100
Air
(12)
(3)
30'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
4.29
7.8
100
Air
(13)
(3)
32'
750
18
°
41
°
36
°
50 to
Opt.
Forced 8" x 10
°
50 min.
5.94
10.8
100
Air
(14)
(3)
•Hussmann Chino reserves the right to change or revise case specifications and design in connection with any feature of our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions, or replacement of equipment previously sold or shipped. These changes may also affect the loads applicable to a particular case,
therefore always check the serial plate at the back of the case and/or consult the factory for the current loads for your particular equipment.
Summary of Contents for Chino DBP Series
Page 18: ...IGIP DBP DBRP 01 03 0210 18...