IGSS-RCD-0105
6
Electrical
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heat-
ers, Thermostats, and Lights.
WIRING COLOR CODE
G R E E N
G RO U N D
P U R P L E
A N T I - S W E AT
O R A N G E
L I G H T S
Y E L L OW
R E C E P TA C L E
R E D / B L A C K
T- S TAT / S O L E N O I D 230V
BLACK / WHITE
T- S TAT / S O L E N O I D 115V
B ROW N
FAN MOTORS
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual
configuration as checked in the “TYPE INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length
fluorescent lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the
rear of the case mullion.
FIELD WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration
control panel to the merchandisers is required for
refrigeration thermostats. Most component amperes
are listed in the “Case Specs” section, but always check
the serial plate.
BALLAST LOCATION (OPTIONAL)
Ballasts are located under the case below the on/off
switch on the right hand side. the ballast box is 4” x 4”
x 18”.
Optional
Light
RCD - Remote
Shown with Options
Scale = 3/4"
Ballast
RCD - SC
Shown with Refrigerated Rear Storage
Scale = 3/4"
Ballast
COIL
Ballast
RCD - SC
Plan View
Shown with Refrigerated Rear Storage
Rear Storage
RCD - SC