rev. 0608
9
Joint trim
After cases have been leveled and joined, and refrigeration,
electrical, and waste piping work completed, install the
splashguards and joint trim where necessary. Fasten the
splash guards along the top edge, or center, with 3/8"
long sheet metal screws. If needed, use silicone sparingly
to caulk the joint trim and exterior body panels with an
appropriate colored silicone to ensure that a cleanable
and professional appearance is achieved. Use a finger in
a clean rag, as you go, to create smooth and neat joints,
while the silicone is still fluid.
DO NOT SEAL JOINT TRIM OR SPLASHGUARDS TO
THE FLOOR!
installation (Cont'd)