14
Front Coils
controlled by
EPR Valve
under
Deck Pan
T-Stat &
Ballast Are
Labeled as
Such
(Located in the
same place for
hot and cold)
Optional
T-Stat and
Solenoid
(Right Side)
Figure #3
Refrigeration Data
Note: This data is based on store temperature and humidity
that does not exceed 75F and 55% R.H.
Front
Top
See Spec Sheet
Note: Not recommended to control temp by regulating coil
temp allow T-STAT to cycle and control temp.
Front
Top
Btu/hr/ft*
See Spec sheets
Parallel
Conventional
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Defrost Data
See Spec Sheets
Frequency Hrs
OFFTIME
Temp Term °F
Failsafe Minutes
ELECTRIC or GAS Not Recommended
Refrigeration (Cont'd)
Physical Data
Merchandiser Drip Pipe (in.)
1½*
Merchandiser Glycol Pipe (in.)
7/8*
Merchandiser Liquid Line (in.)
3/8*
Merchandiser Suction Line (in.)
5/8*
Estimated Charge (lb)***
4ft
1.2
5ft
1.5
6ft
1.8
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GLYCOL REQUIREMENTS
GPM
PSI
NA
NA
NA
NA
NA
NA