background image

Medium Temperature

P/N 428668A

1-1

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)

NSF CERTIFICATION

These merchandisers are manufactured to meet
ANSI / National Sanitation Foundation (NSF

®

)

Standard #7 requirements. Proper installation is
required to maintain certification. Near the serial
plate, each case carries a label identifying the type
of application for which the case was certified.

ANSI/NSF-7 Type I – Display Refrigerator / Freezer

Intended for 75°F / 55%RH Ambient Application

ANSI/NSF-7 Type II – Display Refrigerator / Freezer

Intended for 80°F / 55%RH Ambient Application

ANSI/NSF-7 – Display Refrigerator 

Intended for Bulk Produce

LOCATION

These merchandisers are designed for displaying
products in air conditioned stores where tempera-
ture is maintained at or below the ANSI / NSF-7
specified level and relative humidity is maintained
at or below 55%. 

Placing refrigerated merchandisers in direct sun-
light, near hot tables or near other heat sources
could impair their efficiency.

Like other merchandisers, these are sensitive to air
disturbances. Air currents passing around merchan-
disers will seriously impair their operation. Do
NOT allow air conditioning, electric fans, open
doors or windows, etc. to create air currents around
the merchandisers.

Product should always be maintained at proper
temperature. This means that from the time the
product is received, through storage, preparation
and display, the temperature of the product must
be controlled to maximize the life of the product.

The exterior frames on these cases provide space
for air circulation. However, in high ambient 
conditions, sweating may still occur. If this 
happens install a method of forced ventilation such
as a fan ventilation kit.

Wide Island Fronts
B

E SURE TO POSITION WIDE ISLAND MERCHANDISER

FRONTS

PROPERLY

. The front of wide island 

merchandisers is readily identified by the location
of the serial plate (see leveling drawing on next
page). Since all electrical and refrigeration 
connections will be made at the front side, the
fronts will need to be positioned according to the
store plan layout.

SHIPPING DAMAGE

All equipment should be thoroughly examined for
shipping damage before and during unloading.

This equipment has been carefully inspected at our
factory. Any claim for loss or damage must be
made to the carrier. The carrier will provide any
necessary inspection reports and/or claim forms.

Apparent Loss Or Damage
If there is an obvious loss or damage, it must be
noted on the freight bill or express receipt and
signed by the carrier’s agent; otherwise, carrier
may refuse claim. 

Concealed Loss Or Damage
When loss or damage is not apparent until after
equipment is uncrated, retain all packing materials
and submit a written request to the carrier for
inspection, within 15 days.

INSTALLATION

Do not walk or put heavy objects on case.

CAUTION

!

Summary of Contents for CW2-BGE

Page 1: ...uce Merchandisers Installation Operation Manual Shipped With Case Data Sheets P N 428668A Impact Series August 2001 I IM M P P O O R R T TA A N N T T K K e ee ep p i in n s st to or re e f fo or r f f...

Page 2: ...cking 4 1 Load Limit Profile 4 2 Shelf Alignment 4 2 Multideck Shelf Configuration 4 2 Installing Lighted Shelves 4 2 Installing FDA NSF Required Thermometer 4 4 MAINTENANCE Care and Cleaning 5 1 Clea...

Page 3: ...This means that from the time the product is received through storage preparation and display the temperature of the product must be controlled to maximize the life of the product The exterior frames...

Page 4: ...se as possible to its permanent location and then remove all packaging Check for damage before discarding packaging Remove all separately packed accessories such as kits and shelves LEVELING Merchandi...

Page 5: ...handiser as shown 2 Apply the 1 2 in 13 mm gasket around the perimeter of case and across the top as shown Be sure to overlap gaskets as shown Check to be sure that there are no gaps between gasket an...

Page 6: ...inside each case Install splashguard brackets before piping case Use two screws per bracket Attach brackets every 4 feet at pre drilled locations Install splashguard brackets on faceted end in locatio...

Page 7: ...one end carefully peel bottom of top rail free of the retainer and set the rail inside the case c Remove bumpers by pulling bumper away from bumper retainers There are no starter bumpers in the CW2 fa...

Page 8: ...ast bumpers and top rail to length Install the last sections Note If part of plastic top rail pops loose remove that section of top rail and re install according to Step 5 Trying to re install only th...

Page 9: ...ing on the same refrigeration system may be run from merchandis er to merchandiser DO NOT RUN REFRIGERANT LINES THROUGH MERCHANDISERS THAT ARE NOT ON THE SAME REFRIGERATION SYSTEM BRANCH as this may r...

Page 10: ...r lines are exposed to ambient conditions SUCTION LINE Pitch in direction of flow May be reduced by one size at one third of case run load and again after the second third Do not reduce below the case...

Page 11: ...disers require defrost cycles for proper operation Refer to the data sheets for appli cation data The Time Clock initiates defrost The evaporator fans continue to circulate air across the evaporator c...

Page 12: ...circuit the defrost termination thermostats are wired in series ALWAYS CHECK THE SERIAL PLATE FOR COMPO NENT AMPERES IDENTIFICATION OF WIRING Leads for all electrical circuits are identified by colore...

Page 13: ...t of the drip piping to prevent air leakage or insect entrance Never use two water seals in series in any one drip pipe DOUBLE WATER SEALS IN SERIES WILL CAUSE AN AIR LOCK AND PREVENT DRAINING 3 Pitch...

Page 14: ...e waste outlet can be inter connected A drain piping connect kit is required to change piping from front to back as shown Each merchandiser is supplied with a 2 in 51mm water seal an adapter a plug an...

Page 15: ...ashguard match the tabs extending from the base of the case as shown 3 Push splashguard up onto tabs until lower edge of splashguard swings onto bracket Lower bot tom of splashguard onto bracket tabs...

Page 16: ...rease from the area of the splashguard where adhesion will be nec essary This is to ensure a good and secure installation 2 Apply a good contact cement to the cove trim and allow proper drying time ac...

Page 17: ...LOAD LIMITS INDICATED DO NOT BLOCK HONEYCOMB STOCKING Hussmann recommends one or two shelves be used in each CW2 merchandiser section and two or three shelves be used in each CW2X merchandiser section...

Page 18: ...s will lock them together MULTI DECK SHELF CONFIGURATION The bottom display shelves can be adjusted to accommodate shallow or volume displays bulky items such as hams or chickens The upper shelves are...

Page 19: ...sockets 4 Verify that power is at the case and turned on Verify that the case light switch is turned OFF Switch is located in the canopy on the left behind first row of lamps 5 See the illustration b...

Page 20: ...n contrac tor 9 Using the row of shelves just installed as support set the next shelf X 4 in the desired location Remove the cap and insert the shelf plug Continue working left to right installing she...

Page 21: ...tions in Multi deck Merchandisers Return Air Grille Shelf Price Tag Molding Suggested Mounting Locations in Single Deck Glass Front Impact Merchandisers Acrylic Package Guard Facing Out Double Stick T...

Page 22: ...warmest part of a mechan ically refrigerated unit and in the coolest part of a hot FOOD storage unit B Except as specified in C of this section cold or hot holding EQUIPMENT used for POTENTIALLY HAZA...

Page 23: ...eaning be sure the plenum is properly lowered into position or product loss will result due to improper refrigeration Extra care must be taken when cleaning the CW2 end compartments as the left and ri...

Page 24: ...R Take care to minimize direct contact between fan motors and cleaning or rinse water Rinse with hot water but do NOT flood NEVER INTRODUCE WATER FASTER THAN THE WASTE OUTLET CAN REMOVE IT Allow merch...

Page 25: ...nd remove it from its retainer 2 Clean and dry the honeycomb 3 After cleaning replace in reverse order REMOVING INTERIOR BACK PANELS The interior back panels may be removed for cleaning and to gain ac...

Page 26: ...hment to remove accumulated dust and debris from under the mer chandiser REMOVING SCRATCHES FROM BUMPER Most scratches and dings can be removed using the following procedure 1 Use steel wool to smooth...

Page 27: ...ng bottom of motor to fan basket 6 Replace fan motor and blade 7 Lower fan plenum 8 Reconnect fan to wiring harness 9 Turn on power 10 Verify that motor is working and blade is turn ing in the correct...

Page 28: ...in reverse order 9 Turn on power 10 Verify that motor is working and blade is turn ing in the correct direction 11 Close air gaps under fan plenum Warmer air moving into refrigerated air reduces effe...

Page 29: ...e Hussmann Impact lamp holder is designed to snap into the sheet metal of the case The lamp holder has a locking nub which fits inside the groove of specially designed end caps IMPORTANT Always replac...

Page 30: ...Remove the screws that secure the light panel 4 Grasping the light panel at the area where the panel and the canopy meet pull back and down until the panel swings freely Note Light panels in the end...

Page 31: ...in fitting Be sure to drill completely through fitting and bottom liner 2 Apply teflon tape to threaded end of adapter and screw into threaded end of tee 3 Apply an ABS and PVC compatible primer and s...

Page 32: ...Irving TX 75062 Phone 1 800 527 9916 NOTE Hussmann Aluminum melts at 1125 F 607 C Aladdin 3 in 1 rod at 732 F 389 C X Ergon Acid core at 455 F 235 C Technique 1 Locate Leak 2 REMOVE ALL PRESSURE 3 Bru...

Page 33: ...ct your Hussmann representative Please include the model and serial number of the product The full product warranty is available from our website www hussmann com Hussmann Corporation Corporate Headqu...

Reviews: