Medium Temperature
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)
REPLACING DAMAGED DRAIN FITTING
The following procedure is for the field repair of a
broken drain fitting.
1. Use a drill with a 1
7
/
8
-in. (48 mm) hole saw to
drill out the bottom of the drain fitting. Be sure
to drill completely through fitting and bottom
liner.
2. Apply teflon tape to threaded end of adapter
and screw into threaded end of tee.
3. Apply an ABS and PVC compatible primer
and sealer to adapter and inside of drain. Insert
adapter into drain fitting.
Drain Fitting
Viewed from Inside Merchandiser
Foam Bottom Assembly
Modified
Drain Fitting
PVC Adapter
1
1
/
2
x 1
1
/
4 inch
(38 x 32 mm)
(obtained at local building supply store)
Tee 1
1
/
4 in.
(32 mm)
TxSxS
End Section View