Medium Temperature
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)
REPLACING FAN MOTORS AND BLADES
See cross section for location of evaporator fans.
Should it ever be necessary to service or replace
the fan motors or blades be certain that the fan
blades are re-installed correctly. T
HE BLADES
MUST BE INSTALLED WITH RAISED EMBOSSING
(
PART NUMBER ON PLASTIC BLADES
)
POSITIONED
AS INDICATED ON THE PARTS LIST
. (Refer to the
case data sheet for each model.)
For access to these fans:
1. Turn off power
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Remove fan blade.
5. Lift fan plenum and remove screws holding
bottom of motor to fan basket.
6. Replace fan motor and blade.
7. Lower fan plenum.
8. Reconnect fan to wiring harness.
9. Turn on power
10. Verify that motor is working and blade is turn-
ing in the correct direction.
11. Ensure the plenum rests on the case bottom
with no gaps.
12. Replace display pans, Bring merchandiser to
operating temperature before restocking.
CW2 Unitized End
For access to these fans:
1. Turn off power
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Lift off the rear shelf support.
Always disconnect the electrical
power at the main disconnect when
servicing or replacing any electrical
component. This includes, but is not
limited to, such items as fans, heaters,
thermostats and lights.
WARNING
!
Remove
Screws
Hook to Back Panel
Left Shelf Support
Do NOT allow product to sit in a
non-refrigerated area.
WARNING
!