background image

D

C

E

B

A

D

E

E

F

G

P/N 0463855_D

D5X-LE

Technical Data Sheet

P/N  0463855_D

NSF

®

Certified

March  2008

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

4 Ft, 8 Ft, 10 Ft

& 12 Ft

A.

12W Standard

Fan Assembly 

(1)

0047000

Fan Motor, Evaporator
(MO.4410103)

0461805

Fan Blade (FB.4780446)

12W Energy Efficient

Fan Assembly 

(1)

0477655

Fan Motor, Evaporator 
(MO.4410546)

0461805

Fan Blade (FB.4780446)

6 Ft and 10 Ft

Only 

A.

7W Standard 

Fan Assembly  

(1)

0058698

Fan Motor, Evaporator
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient

Fan Assembly 

(1)

0477654

Fan Motor, Evaporator
(MO.4410545)

0142780

Fan Blade (FB.0142780)

10 Ft uses both.

Item Part #

Description

Wiring Item #

T

HERMOSTATS

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat
(CT.0411744)

C. Optional Adjustable Refrigeration Thermostat (3)

L

AMPS

. B

ALLASTS

, LED F

IXTURES AND

P

OWER

S

UPPLY

D. Ballast, Electronic

(4)

0480130

2 lamps (BA.4481676)

0480131

3 lamps (BA.4481654)

0480132

4 lamps (BA.4481677)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

F. 0501213

Power Supply (EP.4481861)

(6)

G.

LED Fixture

(7)

Replace with like fixtures

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Note:  Revision D changes ballast (

Page 1

); adds optional LED lighting (

Pages 1, 3, 4, 8

); adds capacity and weight (

Page 5

).

Summary of Contents for D5X-LE

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 10 Ft uses...

Page 2: ...1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electri...

Page 3: ...ly Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb D5X LE 4 ft 1 4 6 ft 1 9 8 ft 2 7 10 ft 3 2 12 ft 3 9 This is an average for all...

Page 4: ...rent Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 0 77 30 59 59 85 85 Optional Lighting T 8 flu...

Page 5: ...3 ft 0 87 m3 m ARI Total Display Area 3 Sq Ft Ft 4 86 ft2 ft 1 48 m2 m Shelf Area 4 Sq Ft Ft 9 89 ft2 ft 3 02 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Len...

Page 6: ...L BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All component...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: