background image

D5X-LE 

Technical Data Sheet 

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

4 of 8

Impact  

Excel 

D5X-LE

Dairy & Delicatessen

Electrical Data

4 ft

6 ft

8 ft

10 ft

12 ft

Number of Fans – 12W

1

2

1

3

Number of Fans – 7W

2

2

Amperes

Watts

4 ft

6 ft

8 ft

10 ft

12 ft

4 ft

6 ft

8 ft

10 ft

12 ft

Evaporator Fans

120V

60Hz

Standard

0.65

1.00

1.30

1.65

1.95

50

78

100

128

150

120V

50Hz

Standard

0.75

1.10

1.50

1.85

2.25

57

84

114

141

171

230V

60Hz

Export

0.33

0.50

0.66

0.83

0.99

50

78

100

128

150

230V

50Hz

Export

0.38

0.56

0.76

0.94

1.14

57

84

114

141

171

120V

60Hz

Energy Efficient

0.30

0.38

0.60

0.68

0.90

18

28

36

46

54

230V

60Hz

Energy Efficient

0.15

0.20

0.30

0.35

0.45

18

28

36

46

54

Minimum Circuit Ampacity

120V

60Hz

Standard

0.85

1.20

1.50

1.85

2.15

120V

50Hz

Standard

0.95

1.30

1.70

2.05

2.45

230V

60Hz

Export

0.53

0.70

0.86

1.03

1.19

230V

50Hz

Export

0.58

0.76

0.96

1.14

1.34

120V

60Hz

Energy Efficient

0.50

0.58

0.80

0.88

1.10

230V

60Hz

Energy Efficient

0.35

0.40

0.50

0.55

0.65

Maximum Over Current Protection 120V

20

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

15

Standard Lighting (T-8 fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

0.77

30

59

59

85

85

Optional Lighting (T-8 fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

0.77

30

59

59

85

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

1.54

59

118

118

170

170

Additional 3 Row Canopy

0.77

1.53

1.53

2.31

2.31

89

177

177

255

255

1 Row Rail Light

0.26

0.51

0.51

0.77

0.77

30

59

59

85

85

Optional Shelf Lighting (T-8 fluorescent)

1 Row of Shelves

0.26

0.51

0.51

0.77

0.77

30

59

59

85

85

4 Rows of Shelves

1.02

2.04

2.04

3.08

3.08

118

236

236

340

340

5 Rows of Shelves

1.28

2.55

2.55

3.85

3.85

148

295

295

425

425

6 Rows of Shelves

1.53

3.06

3.06

4.62

4.62

177

354

354

510

510

Optional Always*Bright LED Lighting

1 Row of Shelves

0.15

0.19

0.26

0.30

0.38

18

23

31

36

45

4 Rows of Shelves

0.47

0.68

0.93

1.15

1.40

56

82

112

138

168

5 Rows of Shelves

0.57

0.83

1.13

1.38

1.69

68

99

136

166

203

6 Rows of Shelves

0.67

0.96

1.33

1.62

2.00

80

115

160

194

240

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

Summary of Contents for D5X-LE

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 10 Ft uses...

Page 2: ...1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electri...

Page 3: ...ly Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb D5X LE 4 ft 1 4 6 ft 1 9 8 ft 2 7 10 ft 3 2 12 ft 3 9 This is an average for all...

Page 4: ...rent Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 0 77 30 59 59 85 85 Optional Lighting T 8 flu...

Page 5: ...3 ft 0 87 m3 m ARI Total Display Area 3 Sq Ft Ft 4 86 ft2 ft 1 48 m2 m Shelf Area 4 Sq Ft Ft 9 89 ft2 ft 3 02 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Len...

Page 6: ...L BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All component...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: