background image

7 of 8

P/N 0463859_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

5

R

BL

5

R

BL

BL

R

BL

R

5

R

BL

BL

4

5

5

5

B

W

BL

BL

R

BL

BL

BL

W

R

W

R

B

R

4

B

BL

BL

BL

R

R

R

R

5

R

BL

5

R

BL

BL

R

BL

R

5

R

BL

BL

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Six Rows of Shelves

4 ft case

Connector

4

5

5

5

B

W

Connector

6 ft or 8 ft case

12 ft case

BL

BL

R

BL

BL

BL

W

R

W

R

B

R

4

B

BL

BL

BL

R

R

R

R

5

R

BL

5

R

BL

BL

R

BL

R

5

R

BL

BL

4

5

5

5

B

W

BL

BL

R

BL

BL

BL

W

R

W

R

B

R

4

B

BL

BL

BL

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Summary of Contents for D6NX-LE

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part D...

Page 2: ...external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2...

Page 3: ...X LE 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb D6NX LE 4 ft 1 4 6 ft 1 9 8 ft 2 7 12 ft 3 9 This is...

Page 4: ...30V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51...

Page 5: ...70 m3 m ARI Total Display Area 3 Sq Ft Ft 5 25 ft2 ft 1 60 m2 m Shelf Area 4 Sq Ft Ft 8 81 ft2 ft 2 69 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Page 6: ...nector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL...

Page 7: ...RAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: