REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
D6X-URLE
Discharge Air (°F)
27
Evaporator (°F)
21
Unit Sizing (°F)
19
Important Note:
Btu numbers are for the D6X-
URLE when installed to a cooler operating at a
36
°
F air temperature. The unit cooler coil must
be sized for an
additional load of 1160
Btu/hr/ft of D6X-URLE
case installed to the
cooler.
Btu/hr/ft
D6X-URLE
Parallel
1200
Conventional
1375
DEFROST DATA
D6X-URLE
Frequency (hr)
6
Defrost Water (lb/ft/day)
6
(± 15%
based on case configuration and
product loading).
O
FF
T
IME
D6X-URLE
Time Terminated (minutes)
45
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat — NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D6X-URLE
CI/CO (Temp °F)
*
14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
NA
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge (lb)**
6 ft
2.0
8 ft
2.7
12 ft
3.9
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
P/N 0498329_C
Fan
Coil
Fan
40
7
/
8 (1038)
41
5
/
8 (1057)
44
(1118)
45
3
/
8 (1153)
34
7
/
8 (886)
33
7
/
8 (860)
24
5
/
8 (626)
6
3
/
8
(162)
51
5
/
8 (1311)
83
1
/
2
(2121)
90
(2286)
4
1
/
8 (106)
7
1
/
4
(184)
11
1
/
2
(292)
92
1
/
8
(2340)
10
1
/
4
(260)
12
3
/
4
(324)
3
(76)
29
7
/
8 (758)
67
3
/
4
(1721)
2
1
/
8
(54)
C
O
O
L
E
R
W
A
L
L
3
3
/
4
(95)
C
O
O
L
E
R
W
A
L
L
70
1
/
2
(1791)
Dimensions shown as in. & (mm).
Ultra Low Front, Rear Load
3 of 9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
D6X-URLE
Dairy
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.
ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE.
D6X-URLE