Electrical Data
Number of Fans
6 ft
8 ft
12 ft
Discharge — 13W
4
4
6
Return — 12W
—
4
6
Return — 7W
4
—
—
Amperes
Watts
6 ft
8 ft
12 ft
6 ft
8 ft
12 ft
Discharge Fan
120V
60Hz
Standard
3.08
3.08
4.62
244
244
366
120V
50Hz
Standard
3.92
3.92
5.88
280
280
420
230V
60Hz
Export
1.56
1.56
2.34
244
244
366
230V
50Hz
Export
1.92
1.92
2.88
280
280
420
120V
60Hz
Energy Efficient
1.20
1.20
1.80
80
80
120
230V
60Hz
Energy Efficient
0.60
0.60
0.90
80
80
120
Return Fan
120V
60Hz
Standard
2.00
2.60
3.90
156
200
300
120V
50Hz
Standard
2.20
3.00
4.50
168
228
342
230V
60Hz
Export
1.00
1.32
1.98
156
200
300
230V
50Hz
Export
1.12
1.52
2.28
168
228
342
120V
60Hz
Energy Efficient
0.76
1.20
1.80
56
72
108
230V
60Hz
Energy Efficient
0.40
0.60
0.90
56
72
108
Minimum Circuit Ampacity
120V
60Hz
Standard
5.28
5.88
8.72
120V
50Hz
Standard
6.32
7.12
10.58
230V
60Hz
Export
2.76
3.08
4.52
230V
50Hz
Export
3.04
3.64
5.36
120V
60Hz
Energy Efficient
2.16
2.60
3.80
230V
60Hz
Energy Efficient
1.20
1.40
2.00
Maximum Over Current Protection 120V
20
20
20
Maximum Over Current Protection 230V
15
15
15
Standard Lighting
1 Row Canopy
0.51
0.51
0.77
59
59
85
Optional Lighting
Additional 1 Row Canopy
0.51
0.51
0.77
59
59
85
Additional 2 Row Canopy
1.02
1.02
1.54
118
118
170
1 Row Rail Light
0.51
0.51
0.77
59
59
85
Lighted shelves are not available for rear-load models.
120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D6X-URLE
Technical Data Sheet
4 of 9
Impact
Excel
D6X-URLE
Dairy