1-6
I
nstallatIon
P/N 0467434_P
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
remove the fasteners holding the retainers for
the discharge air louvers. (Lift louvers up and
out from the bottom.) Remove any return air
flue plex-glass parts. (Lift up on interior panels
to remove.) See 1-14 for replacement.
NOTE
:
FWE and FWEG end merchandisers have
joining fasteners inserted in the appropriate
locations. Remove nuts and washers from
outside of end merchandiser before attempting
to join.
Apply Gaskets to Right End
1. Apply the 1
5
/
8
in. (41 mm) gasket around
the perimeter of the merchandiser as shown.
It must be at the edge. Check to be sure
that there are no gaps between gasket and
merchandiser.
2. Apply the 1 in. (25 mm) gasket across the
end shoe as shown. Each end of the gasket
should extend onto the 1
5
/
8
inch gasket but not
over. Check to be sure that there are no gaps
between merchandiser and gaskets.
3. On narrow and intermediate islands, wall
merchandisers, and cases, apply the 1 in.
(25 mm) gasket at the top of the discharge and
return air flues as shown. On wide islands,
apply the 1 in. (25 mm) gasket at the top of
return air flues as shown. Apply the 1
5
/
8
in.
(41 mm) gasket at the top of the discharge
(center) flue as shown.
NOTE:
When adding an end merchandiser,
apply gaskets to the wide island, not the end
merchandiser.
JOINING MERCHANDISERS IN LINE
IMPORTANT
• Do not stretch gasket,
especially around corners.
• Do not butt gaskets;
always overlap them as shown.
• Remove paper backing
after gasket has been applied.
•
Perimeter gasket is
required
by NSF.
Lap Gasket(s)