Low Temperature
Excel
P/N 0467434_P
1-15
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Seal Merchandisers
1. Remove wire rack, rack supports and
interior panels to apply butyl tape.
2. Apply butyl tape across the bottom joint.
Be sure to extend the tape up the back and
front of the merchandiser.
Silicone sealer may be applied around joining
bolts on both sides in bottom shoe.
INSTALLING SPLASHGUARD
BRACKETS
Position splashguard brackets to the
merchandiser and level to the floor. Each
bracket has a 1
1
/
2
in. (38 mm) slot at the
rear of the bracket where it attaches to the
merchandiser. Tighten screws to secure the
brackets.
Important:
Install splashguard brackets before
installing drip piping.
REPLACING INTERIOR PANELS AND
DISCHARGE AIR LOUVERS
After case joining is complete and all joining
bolts are fastened, re-install the interior front
and back panels. Special care needs to be
taken when re-installing the discharge air
louvers. The flange at the top of the louver
must properly fit into the correct position in
the extrusion. Incorrect position of the louver
can cause the plastic nosing on the anti-sweat
heater to become dislodged. See details in
Section 6 for correct steps to re-install plastic
nosing extrusion.
Splashguard
Bracket
Screw
Leg
Anti-Sweat Heater
Plastic Nosing
Discharge Air Louver
Louver Retainer
Retainer Fastener
Discharge Air Louver