6-6
s
eRVIce
P/N 0467434_P
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
Hand Rail Heater Connections are Located in Left
Front Corner of Merchandiser (Near Serial Plate)
Hand R ail
(Front)
(Front)
FWEG Heater Connections are at Right Rear Corner
of Merchandiser
Metal top rail must be properly grounded.
7. Disconnect and remove hand rail heater
from wireway.
8. Replace heater connections and re-route
new heater through internal front joint trim
and onto hand rail retainers as shown.
9. Clean rail surfaces thoroughly, then install
new hand rail heater.
10. Reinstall parts in reverse order. Any
damaged parts must be replaced.
R emove Screw
R emove
C orner Cap
G rounding Wire
Harness
G rounding Wire
Harness
C orner Cap
B racket
S crew
— LOCK OUT / TAG OUT —
To avoid serious injury or death from electrical
shock, always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.