P/N 0467434_P
6-11
Low Temperature
Excel
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
REPLACING DRIP PAN HEATER
1. Turn off power to the merchandiser.
2. Remove wire racks and display pans from
the compartment being serviced.
3. Unplug the heater from the heater harness.
4. Remove heater lead wire from interior
panel supports.
5. Remove all screws and clips, then remove
the heater.
6. Position the new heater. Apply new acrylic
sealer to the underside of clips. Carefully
reinstall clips in their original position
.
7. Route heater lead wire through the interior
panel supports.
8. Reconnect harness.
9. Turn on power to merchandiser and check
for proper operation.
10. Reinstall display pans and wire racks.