background image

FNG  

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

4 of 7

Impact  

Excel

FNG

Low / Medium Temperature 

Electrical Data

8 ft

10 ft

12 ft

Number of Fans – 4W Evaporator

2

2

2

Amperes

Watts

8 ft

10 ft

12 ft

8 ft

10 ft

12 ft

Evaporator Fans

120V

60Hz

Standard

0.62

0.62

0.62

48

48

48

120V

50Hz

Standard

0.76

0.76

0.76

54

54

54

230V

60Hz

Export

0.30

0.30

0.30

48

48

48

230V

50Hz

Export

0.36

0.36

0.36

54

54

54

120V

60Hz

Energy Efficient

0.24

0.24

0.24

16

16

16

230V

60Hz

Energy Efficient

0.12

0.12

0.12

16

16

16

Anti-sweat Heaters (on fan circuit)

120V

50/60Hz Standard

0.87

1.07

1.30

104

128

156

230V

50/60Hz Export

0.45

0.56

0.68

104

128

156

Minimum Circuit Ampacity

120V

60Hz

Standard

1.69

1.89

2.12

120V

50Hz

Standard

1.83

2.03

2.26

230V

60Hz

Export

0.95

1.06

1.18

230V

50Hz

Export

1.01

1.12

1.24

120V

60Hz

Energy Efficient

1.31

1.51

1.74

230V

60Hz

Energy Efficient

0.77

0.88

1.00

Maximum Over Current Protection 120V

20

20

20

Maximum Over Current Protection 230V 

15

15

15

Return Glass Anti-sweat Heaters

120V

50/60Hz Standard

0.08

0.11

0.11

9

13

13

230V

50/60Hz Export

0.04

0.06

0.06

9

13

13

Discharge Glass Anti-sweat Heaters

120V

50/60Hz Standard

0.46

0.66

0.66

55

79

79

230V

50/60Hz Export

0.24

0.34

0.34

55

79

79

208V Electric Defrost

7.69

9.61

11.54

1600

2000

2400

230V Export Electric Defrost

6.96

8.70

10.43

1600

2000

2400

120V Koolgas Defrost

1.67

2.50

3.33

200

300

400

Standard Lighting

None

Summary of Contents for FNG

Page 1: ...Anti sweat Heaters 8 0495007 8 ft case HE 4850685 0497590 10 ft case HE 4850712 0495008 12 ft case HE 4850686 H Return Grille Anti sweat Heaters 9 0495011 8 ft case HE 4850689 0497582 10 ft case HE 4...

Page 2: ...enter legs 41 1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 3 1 8 82 3 1 8 82 3 1 8 82 Electrical Service...

Page 3: ...ly Pressure Defrost Termination Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 8 ft 2 0 10 ft 2 5 12 ft 3 0 This is an average for all refrigerant t...

Page 4: ...230V 50 60Hz Export 0 45 0 56 0 68 104 128 156 Minimum Circuit Ampacity 120V 60Hz Standard 1 69 1 89 2 12 120V 50Hz Standard 1 83 2 03 2 26 230V 60Hz Export 0 95 1 06 1 18 230V 50Hz Export 1 01 1 12 1...

Page 5: ...t Ft 3 69 ft3 ft 0 34 m3 m ARI Total Display Area 3 Sq Ft Ft 2 78 ft2 ft 0 85 m2 m Shelf Area 4 Sq Ft Ft 2 79 ft2 ft 0 85 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3...

Page 6: ...ation Thermostat Optional 1 BROWN BAND Fans BROWN BAND Nosing Anti sweat Heater 120V POWER 120V NEUTRAL 8 9 Return Grille Anti sweat Heater WARNING All components must have mechanical ground and the m...

Page 7: ...W HUSSMANN COM Gas Defrost Optional WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers 7 4 120V Drip Pan Heater Koolgas On...

Reviews: