STAR T UP PROCEDURE –
•
After the wiring has been completed, set
the defrost timer for the correct time of
day, making sure the defrost pins are se-
cure in the face of the clock. The GIM-6 is
factory s et for 2 defr ost periods in a
24 hour span. (6 a.m. and 6 p.m.)
•
Cut t he band holding the compre ssor in
place during shipping.
•
Check the cabinet thoroughly for loose
nuts and bolts and electrical connections.
Inspect the re frigerat ion lines for any
visible damage or chafing.
•
Replace the electrical box cover.
•
Start the cabinet and allow to pull down to
operating temperat ure before loading.
DIMENSIONS –
CU
FT EXTERIOR
MODEL
CAP.
L
W H
G
IM-6 8.
8
7
2” 4
0” 48
3/4”
ELECTRICAL –
UNIT
MODEL
H.
P. HZ/PH VOLTS
G
IM-6
3/4
60/1 115*
RUN FUSE SHIP
AMPS S
IZE
WT
12.
0
2
0
AMP 8
00
* 115 V/20 AMP GROUNDED POWER CORD IN-
CLUDED
BTU CAPACITY –
Cases us e R-502 refrigerant prior to 6/8/9 5.
After this date they were changed to R-40 4a.
Check the serial plate for specific ref rig erant
used.
CARE AND CLEANING –
To insure good sanitation, appearance,
and minimum maint enance, the cabinet should
be cleaned and washed regularly as use de-
mands. Clean with a mild detergent and warm
wate r. DO NOT USE AN ABRASIVE
CLEANER OR STEEL WOOL AS THEY
WILL MAR THE FINISH.
ROUTINE MAINTENANCE –
Under normal conditions, aft er the cabi-
net is installed and running, very little mainte-
nance should be required. However, t he fol-
lowing list of housekeeping practices will as -
s ure trouble-free operation.
1. Check operation of condenser fan motors.
Fan blades must turn freely.
2. Check drain pan to prevent accide ntal
overflow. Check alignment of drain stub
going int o pan.
3. Make sure doors are closing properly and
that the doors s eal.
4. Make sure all evaporator fan motors are
running.
5. Keep the honeycomb and return grill free
of ice. The honeycomb is removable for
cleaning. A condens ate heater is installed
above the discharge honeycomb, effective
Nov. 1997 to preve nt ice build-up.
RATING TE MPS Fº
MODEL B
TU/HR EVAP
COND AMB
G IM-6
4600 -25
1
10
90