4 of 8
C2-EP
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
C2-EP
Dairy / Delicatessen
Precut & Packaged Produce
Electrical Data
4 ft
6 ft
8 ft
12 ft
Number of Fans—6W
1
2
2
3
Amperes
Watts
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
Evaporator Fan
120V
60Hz
Standard
0.50
1.00
1.00
1.50
39
78
78
117
120V
50Hz
Standard
0.55
1.10
1.10
1.65
42
84
84
126
230V
60Hz
Export
0.25
0.50
0.50
0.75
40
80
80
120
230V
50Hz
Export
0.28
0.56
0.56
0.84
44
88
88
132
120V
60Hz
Energy Efficient
0.26
0.52
0.52
0.78
18
36
36
54
230V
60Hz
Energy Efficient
NA
Canopy Anti-sweat Heaters
NA
0.75
0.75
1.00
45
90
90
120
Minimum Circuit Ampacity
120V
60Hz
Standard
0.70
1.95
1.95
2.70
120V
50Hz
Standard
0.75
2.05
2.05
2.85
230V
60Hz
Export
0.45
1.45
1.45
1.95
230V
50Hz
Export
0.48
1.51
1.51
2.04
120V
60Hz
Energy Efficient
0.46
1.47
1.47
1.98
230V
60Hz
Energy Efficient
NA
Maximum Over Current Protection 120V
20
20
20
20
Maximum Over Current Protection 230V
15
15
15
15
Standard Lighting
1 Row Canopy
0.26
0.51
0.51
0.77
30
59
59
85
Optional Lighting
Additional 1 Row Canopy
0.26
0.51
0.51
0.77
30
59
59
85
Additional 2 Row Canopy
0.51
1.02
1.02
1.54
59
118
118
170
1 Row Rail Light
0.26
0.51
0.51
0.77
30
59
59
85
1 Row Ledge Light
0.26
0.51
0.51
0.77
30
59
59
85
Optional Shelf Lighting
1 Row Shelf Receptacle
0.26
0.51
0.51
0.77
30
59
59
85
2 Row Shelf Receptacle
0.51
1.02
1.02
1.53
59
118
118
177
115V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52