background image

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

C2-LEP

U

NLIT

L

IT

Discharge Air (°F)

33

31

Evaporator (°F)

28

26

Unit Sizing (°F)

26

24

Btu/hr/ft*

U

NLIT

L

IT

Parallel

655

730

Conventional

680

760

*For all refrigeration equipment other than

Hussmann, use conventional Btu values.

DEFROST DATA

C2-LEP

Frequency (hr)

12

Defrost Water (lb/ft/day)

6

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

C2-LEP

Time (minutes)

30

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

C2-LEP

CI/CO

**

19°F / 9°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)***
4 ft 

1.5

6 ft 

2.1

8 ft 

2.7

12 ft 

3.9

***This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

3 of 8

P/N 0457226C

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

(Note*)

(Note*)

(Note*)

(Note*)

(Note* Optional Accessory Items)

19

(483)

3

/

4

 

(95)

12

(305)

48

(1219)

24 

3

/

8

(619)

18

(406)

30 

1

/

2

(775)

FAN

C

O

I

L

3

/

8

(136)

27 

5

/

8

 

(703)

29 

1

/

4

 

(743)

30 

5

/

8

 

(778)

34 

5

/

8

 

(881)

38 

7

/

8

 

(986)

46 

1

/

2

 

(1182)

5

/

8

(219)

C2LEP

LUS

1

/

8

(155)

14 

1

/

8

(359)

19

(483)

Dimensions shown as inches and (mm).

Multi-deck, 3 Display Levels

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

Impact  

C2-LEP

Dairy / Delicatessen 

Precut & Packaged Produce

C2-LEP

Summary of Contents for Impact C2-LEP

Page 1: ...ASSEMBLIES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item HEATERS C Canopy Anti Sweat Heater 3 NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS D Ballast Electronic 4 0376409 2 lamps 0376410 3 lamps E Fluorescent Lamp 5 Replace with...

Page 2: ...2 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between front skid rail and splashguard 7 3 4 199 7 3 4 199 7 3 4 199 7 3 4 199 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 38 1 4 972 64 3 8 1635...

Page 3: ...rmine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 5 6 ft 2 1 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0457226C HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Note Note Note Note Opt...

Page 4: ...70 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0 26...

Page 5: ...ERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G...

Page 6: ...witch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS P...

Page 7: ...placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 º 12 in 15 º 14 in or less 30 º 18 in or less 45 º 18 in or less NOTE Shelves placed in the lower positions may be up to 18 in deep when positioned at a 0 º angle Top Eight 8 Shelf Hole Locations 18 in 18 in 14 in 12 in 0 15 30 45 Angle Maximum Shelf Size 18 in...

Page 8: ...f lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the one piece canopy top panel by moving panel forward slightly to clear flange in front then lifting up 3 Service or replace ballasts as required 4 Reassemble items as they were originally installed NOTE Rail l...

Reviews: