2 of 8
C2SLE Data Sheet Set
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
B
Electrical Connection
Water Seal
(see note)
4
(102)
Waste Outlet
A
46
1
/
2
(1182)
38
7
/
8
(986)
30
5
/
8
(778)
Refrigeration Outlet
29
1
/
4
(743)
34
11
/
16
(881)
27
5
/
8
(703)
C2SLE
11-02
C
C
D
Front
Dimensions shown as in. & (mm).
4 Ft
6 Ft
8 Ft
12 Ft
General
(A)
Case Length
(without ends or partitions)
48
1
/
4
(1226)
72
1
/
4
(1835)
96
3
/
8
(2448)
144
1
/
2
(3670)
Maximum O/S dimension of case back to front
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
(Includes bumper)
Back of case to front of splashguard
38
7
/
8
(987) 38
7
/
8
(987)
38
7
/
8
(987) 38
7
/
8
(987)
Back of case to O/S edge of front skidrail
29
1
/
4
(743)
29
1
/
4
(743)
29
1
/
4
(743)
29
1
/
4
(743)
Width of Skidrail
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
Width of Bottom Front Support
6 (152)
6 (152)
6 (152)
6 (152)
Stub-up area between front skidrail and splashguard
7 (178)
7 (178)
7 (178)
7 (178)
Electrical Service
(B)
RH end of case to the center of LH knockout
40
1
/
4
(1022)
64
1
/
4
(1632)
88
3
/
8
(2245)
136
1
/
2
(3467)
Back O/S of case to center of knockout
34
5
/
8
(881)
34
5
/
8
(881)
34
5
/
8
(881)
34
5
/
8
(881)
Waste Outlet and Water Seal
(C)
Right end of case to center of waste outlet
24
1
/
8
(613)
24
1
/
8
(613)
24
1
/
8
(613)
72
1
/
4
(1835)
Left end of case to center of waste outlet
24
1
/
8
(613)
48
1
/
8
(1222)
72
1
/
4
(1835)
72
1
/
4
(1835)
Back O/S of case to center of waste outlet
27
5
/
8
(703)
27
5
/
8
(703)
27
5
/
8
(703)
27
5
/
8
(703)
Edge of water seal to center of waste outlet
4 (102)
4 (102)
4 (102)
4 (102)
Outside diameter of drip piping lines
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
NOTE: Water seal outlet must clear front skid rail.
C2 & C2G water seal rotation in forward direction only
due to low base.
Refrigeration Outlet
(D)
Right end of case to center of refrigeration outlet
9 (230)
9 (230)
9 (230)
9 (230)
Back O/S of case to center of refrigeration outlet
30
5
/
8
(778)
30
5
/
8
(778)
30
5
/
8
(778)
30
5
/
8
(778)
Engineering
Plan Views