background image

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

BL

R

R

BL

BL

R

5

5

5

5

5

5

R

4

4

B

120V N

EUTRAL

O

R A N G E

 

O R

 T

A N

 B

A N D

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

BL

R

R

BL

BL

4

R

5

5

5

W

=  120V P

OWER

=  120V N

EUTRAL

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

Grayed components in 12 ft models only

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS

Standard Lighting  1 Row Canopy 

Light Circuits

Optional  Lighting  2 Rows Canopy

6 of 8

C2SLE  Data Sheet Set

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Summary of Contents for Impact C2SLE

Page 1: ...LIES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 115V 6W CW 0142780 Fan Blade embossing toward motor 8 in 25 CW B 0411744 Standard Non adjustable 2 disc type Defrost Thermostat C...

Page 2: ...kidrail and splashguard 7 178 7 178 7 178 7 178 Electrical Service B RH end of case to the center of LH knockout 40 1 4 1022 64 1 4 1632 88 3 8 2245 136 1 2 3467 Back O S of case to center of knockout...

Page 3: ...y 6 15 based on case configuration and product loading OFFTIME C2SLE Temp Term F 48 Failsafe min 30 Standard Defrost Thermostat Close on rise close 48 open 33 CONVENTIONALCONTROLS Low Pressure Backup...

Page 4: ...Anti sweat Heaters NA NA NA NA NA NA NA NA Min Circuit Ampacity With Standard Fans 0 70 1 20 1 20 1 70 Energy Efficient 0 46 0 72 0 72 0 98 Export 230V 50 hz 0 48 0 76 0 76 1 04 Max Over Current Prot...

Page 5: ...llow G Green BL Blue B Black W White WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 1 2 3 Fans Optional Shelf Harness...

Page 6: ...BL BL 4 R 5 5 5 W 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded Grayed components in 12 ft models only R Red Y Yellow G Green BL Blue...

Page 7: ...it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 16 in or less 45 16 in or less NOTE Shelves placed in the lower positions may...

Page 8: ...erchandiser when facing case To access the ballast 1 Remove screws at bottom edge of the canopy and rear of the top panel 3 Remove the one piece canopy top panel by moving panel forward slightly to cl...