background image

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0407833B

Note: 

Changed items have been underlined.

Merchandisers

®

D

D

E

B

E

A

C

E

C5E

Data Sheet Set

P/N 0407833B

NSF

®

Certified

August  2004

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0380485

Fan Blade
embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0428648

Ballast, Electronic

2 lamps

(4)

D. 0428649

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

Summary of Contents for impact C5E

Page 1: ...ng Item FAN ASSEMBLIES AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0380485 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace...

Page 2: ...est knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to cent...

Page 3: ...ation Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb C5E 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End or Insulated Partition in 1 1 2 P N 0407833B 3 of 6 HUSSMANN ...

Page 4: ... 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1 Row Rail 1 53 2 31 177 255 1 Row Ledge Lights 0 51 0 77 59 85 Optional Shelf Lighting 1 Row of Shelves 0 51 0 77 59 85 2 Rows of S...

Page 5: ...have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G S...

Page 6: ... NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 R R R Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W ...

Reviews: