background image

2 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C5E 

Data Sheet

Dimensions shown as inches and (mm).

Engineering

Plan View

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum O/S dimension of case back to front 

(includes bumper)

46 

1

/

4

(1174)

46 

1

/

4

(1174)

Back of case to front of splashguard

38 

5

/

(981)

38 

5

/

(981)

Back of case to O/S edge of front skid rail

29 

1

/

(749)

29 

1

/

(749)

Width of skid rail

1

/

(114)

1

/

(114)

RH end of case to outside edge of external support

1

/

2

(140)

1

/

2

(140)

Distance between edges of external support and center support

40 

5

/

(1032)

40 

5

/

(1032)

Distance between edges of center supports

NA

44  (1118)

Stub-up area between front skid rail and splashguard

7 (178)

7 (178)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

RH End of case to center of farthest knockout

88 

3

/

(2245)

136 

1

/

(3467) 

Back of case to center of knockout

35 

3

/

(899)

35 

3

/

(899)

Length of electrical raceway

34 

5

/

(878)

34 

5

/

(878)

Waste Outlet

(C)

RH End of case to the center of waste outlet

24 

1

/

(613)

72 

1

/

(1835)

LH End of case to the center of waste outlet

72 

1

/

(1835)

72 

1

/

(1835)

Back O/S of case to center of waste outlet

27 

1

/

(699)

27 

1

/

(699)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.

Refrigeration Outlet

Back of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

(D)

RH end of case to center of refrigeration outlet

9 (230)

9 (230)

01-2004

5

1

/

2

 

(140)

1

3

/

8

 

(35)

1

/

4

 

(108)

27 

1

/

2

(699)

30 

5

/

8

(778)

46 

1

/

4

(1174)

38 

5

/

8

(981)

29 

1

/

2

(749)

4

1

/

2

 

(114)

(178)

(102)

Waste Outlet

35 

3

/

8

(899)

40 

5

/

8

(1032)

40 

5

/

8

(1032)

Water Seal

(See note)

Refrigeration

Outlet

Electrical

A

Front

B

C

D

72 

1

/

4

(1835)

Meat/Dairy/Delicatessen 

Precut & Packaged 

Produce

Summary of Contents for impact C5E

Page 1: ...ng Item FAN ASSEMBLIES AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0380485 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace...

Page 2: ...est knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to cent...

Page 3: ...ation Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb C5E 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End or Insulated Partition in 1 1 2 P N 0407833B 3 of 6 HUSSMANN ...

Page 4: ... 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1 Row Rail 1 53 2 31 177 255 1 Row Ledge Lights 0 51 0 77 59 85 Optional Shelf Lighting 1 Row of Shelves 0 51 0 77 59 85 2 Rows of S...

Page 5: ...have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G S...

Page 6: ... NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 R R R Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W ...

Reviews: