background image

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum O/S dimension of case back to front 

(includes bumper)

46 

1

/

4

(1174)

46 

1

/

4

(1174)

Back of case to front of splashguard

38 

5

/

(981)

38 

5

/

(981)

Back of case to O/S edge of front skid rail

29 

1

/

(749)

29 

1

/

(749)

Width of skid rail

1

/

(114)

1

/

(114)

RH end of case to outside edge of external support

1

/

2

(140)

1

/

2

(140)

Distance between edges of external support and center support

40 

5

/

(1032)

40 

5

/

(1032)

Distance between edges of center supports

NA

44  (1118)

Stub-up area between front skid rail and splashguard

7 (178)

7 (178)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

RH End of case to center of farthest knockout

88 

3

/

(2245)

136 

1

/

(3467) 

Back of case to center of knockout

35 

3

/

(899)

35 

3

/

(899)

Length of electrical raceway

34 

5

/

(878)

34 

5

/

(878)

Waste Outlet

(C)

RH End of case to the center of waste outlet

24 

1

/

(613)

72 

1

/

(1835)

LH End of case to the center of waste outlet

72 

1

/

(1835)

72 

1

/

(1835)

Back O/S of case to center of waste outlet

27 

1

/

(699)

27 

1

/

(699)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.

Refrigeration Outlet

Back of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

(D)

RH end of case to center of refrigeration outlet

9 (230)

9 (230)

2 of 6

C6GE  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as inches and (mm).

01-2004

5

1

/

2

 

(140)

1

3

/

8

 

(35)

1

/

4

 

(108)

27 

1

/

2

(699)

30 

5

/

8

(778)

46 

1

/

4

(1174)

38 

5

/

8

(981)

29 

1

/

2

(749)

4

1

/

2

 

(114)

(178)

(102)

Waste Outlet

35 

3

/

8

(899)

40 

5

/

8

(1032)

40 

5

/

8

(1032)

Water Seal

(See note)

Refrigeration

Outlet

Electrical

A

Front

B

C

D

72 

1

/

4

(1835)

C6E

C6LE

C6GE
C6HE

Meat/Dairy/Delicatessen 

Precut & Packaged 

Produce

Summary of Contents for Impact C6GE

Page 1: ...de embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Changed items have been und...

Page 2: ... 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Outside diameter of the drip pipe 1 1 2 38 1 1 2 38 NOTE Water seal outlet must clear front skid rail water ...

Page 3: ...mination Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb C6GE 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length in Added to Lineup byEach End or Insulated Partition 1 1 2 3 of 6 P N 0407826C HUSSMA...

Page 4: ...mpacity With Standard Fans 120V 60Hz 3 00 4 40 With Energy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Canopy and 1 Row Rai...

Page 5: ...ll components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Page 6: ...S PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5...

Reviews: