background image

4 of 6

C6GE  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

C6GE

Meat/Delicatessen/Dairy
Precut & Packaged Produce

Electrical Data

8 ft

12 ft

Number of Fans — 9W

4

6

Number of Fans — 9W (Export)

4

6

(Export: 230V 50 hz shown)

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans

Standard (120V 60Hz)

2.80

4.20

210

320

Energy Efficient (120V 60Hz)

1.52

2.28

100

150

Export (230V 50Hz)

1.52

2.28

228

342

Cycling Anti-sweat Heaters

NA

Minimu Circuit Ampacity

With Standard Fans (120V 60Hz) 

3.00

4.40

With Energy Efficient Fans (120V 60Hz)

1.72

2.48

With Export Fans (230V 50Hz) 

1.72

2.48

Maximum Over Current Protection

20

20

Export (230V 50Hz)

15

15

Electric Defrost Heaters (208V 1

Φ

Φ

)

NA

Standard Lighting

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.54

118

170

2 Rows Canopy

1.02

1.54

118

170

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

1 Row Ledge Lights

0.51

0.77

59

85

Optional Shelf Lighting

1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

4 Rows of Shelves

2.04

3.08

236

340

5 Rows of Shelves

2.55

3.85

295

425

Summary of Contents for Impact C6GE

Page 1: ...de embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Changed items have been und...

Page 2: ... 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Outside diameter of the drip pipe 1 1 2 38 1 1 2 38 NOTE Water seal outlet must clear front skid rail water ...

Page 3: ...mination Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb C6GE 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length in Added to Lineup byEach End or Insulated Partition 1 1 2 3 of 6 P N 0407826C HUSSMA...

Page 4: ...mpacity With Standard Fans 120V 60Hz 3 00 4 40 With Energy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Canopy and 1 Row Rai...

Page 5: ...ll components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Page 6: ...S PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5...