background image

5 of 6

P/N 0407826C

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Defrost

Termination

Thermostat

Refrigeration

Thermostat

Dark Blue

3

To
Condensing
Unit

}

Light Blue

2

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=

  

120V

 

P

OWER

=

  

120V

 

N

EUTRAL

=

  

F

IELD 

G

ROUND

=

  

C

ASE 

G

ROUND

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Fan  Wiring

Offtime Defrost

4 & 6 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN 

B

AND

Connector

Connector

G

Connector

Connector

Connector

Connector

Connector

Optional Shelf Harness and Light Circuits for
One Row of Shelves

120 V

Power

B

W

G

B

BL

BL

BL

G

G

R

R

BL

BL G

W

BL

Shelf Harness

Shelf Light Circuits

BL

G

R

5

4

W

BL

R

5

BL

R

G

G

R

R

R

G

Shelf Lighting

G

G

R

BL

5

BL

Connector

Connector

B

Summary of Contents for Impact C6GE

Page 1: ...de embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Changed items have been und...

Page 2: ... 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Outside diameter of the drip pipe 1 1 2 38 1 1 2 38 NOTE Water seal outlet must clear front skid rail water ...

Page 3: ...mination Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb C6GE 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length in Added to Lineup byEach End or Insulated Partition 1 1 2 3 of 6 P N 0407826C HUSSMA...

Page 4: ...mpacity With Standard Fans 120V 60Hz 3 00 4 40 With Energy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Canopy and 1 Row Rai...

Page 5: ...ll components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Page 6: ...S PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5...

Reviews: