CW2-EGE 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

4 of 6

Electrical Data

Number of Fans 

CW2-EGE

Refrigeration – 9W 

2

Merchandiser

Amperes

Watts

Fans (Refrigeration)

Standard (120V 60Hz)

0.76

50

Energy Efficient (120V 60Hz)

(See Note 1 below)

Cycling Anti-sweat Heaters

NA

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz) 

0.96

NA

With Energy Efficient Fans (120V 60Hz)

(See Note 1 below)

Maximum Over Current Protection 120V

20

Electric Defrost Heaters (208V)

NA

NA

Standard Lighting

1 Row Canopy

0.80

40

Optional Lighting

2 Rows Canopy 

(See Note 2 below)

Optional Shelf Lighting

1 Row of Shelves

0.80

40

2 Rows of Shelves

1.60

80

Note 1:

All CW2 end compartments are equipped with energy efficient fan motors as standard.

Note 2:

CW2 end compartments are not available with 2 row canopy lighting due to space constraints.

Impact  

C2W-EGE

Convertible Island End

Summary of Contents for IMPACT CW2-EGE

Page 1: ...STS C 0135966 Ballast Electronic 3 1 lamp BA 4480883 D 0039764 Lamp Starter EP 4481081 4 E Fluorescent Lamp 5 Replace with like fixtures CW2 EGE Technical Data Sheet P N 0399452_C NSF Certified July 2007 2007 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the right to change or revise specifications and product design ...

Page 2: ...rical service to O S edge of front base rail 7 178 RH edge of case to center of knockout 46 7 8 1191 Length of electrical raceway 21 3 8 543 Waste Outlet Front RH edge of case to the center of waste outlet 11 7 8 301 Center of waste outlet to outside of front base rail 3 7 8 98 Water Seal Center of case to center of pipe connection 32 813 Outside diameter of the drip pipe 1 1 4 32 Water seal outle...

Page 3: ...ne PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 4 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb CW2 EGE 1 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End Partition in 1 1 2 3 of 6 P N 0399452_C 48 1219 Front of Case 16 in Shelf 12 in Shelf 10 3 4 273 5 127 32 813 6 3 8 16...

Page 4: ...s 120V 60Hz 0 96 NA With Energy Efficient Fans 120V 60Hz See Note 1 below Maximum Over Current Protection 120V 20 Electric Defrost Heaters 208V NA NA Standard Lighting 1 Row Canopy 0 80 40 Optional Lighting 2 Rows Canopy See Note 2 below Optional Shelf Lighting 1 Row of Shelves 0 80 40 2 Rows of Shelves 1 60 80 Note 1 All CW2 end compartments are equipped with energy efficient fan motors as standa...

Page 5: ... White 120V POWER 120V NEUTRAL Field GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND 2 Defrost Termination Thermostat Refrigeration Thermostat Dark Blue To Condensing Unit Light Blue 3 2 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND ...

Page 6: ...RTMENT LIGHTING SCHEMATIC Standard canopy lighting and optional shelf lighting are shown 4 4 4 4 4 4 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded Grayed components in 12 ft models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS ...

Reviews: