background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

E

A

C

D

B

P/N 0399334B

Merchandisers

®

Note: Changed items have been underlined.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

6W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator 

0142780

Fan Blade
embossing toward motor

B. 0398558

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0144732

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0428648

Ballast, Electronic

2 lamps

(4)

D. 0428649

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

CW2-GE

Data Sheet Set

P/N  0399334B

NSF

®

Certified

February  2005

Summary of Contents for IMPACT CW2-GE

Page 1: ...698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0398558 Standard Non adjustable 2 Defrost Thermostat C 0144732 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures CW2 GE Data Sheet Set P N 0399334B NSF Cert...

Page 2: ...2 1 8 54 2 1 8 54 2 1 8 54 Stub up area between front base rail and splashguard 7 1 4 184 7 1 4 184 7 1 4 184 Electrical Service Note Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 7 178 7 178 7 178 Right end of case to center of knockout 5 127 5 127 5 127 Length of electrical raceway 46 5 8 1184 46 5 8 1184 46 5 8 1184 Waste Outlet B LH End of...

Page 3: ...llel 1480 Conventional 1640 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA CW2GE Frequency hr 6 Defrost Water lb ft day 10 15 based on case configuration and product loading OFFTIME CW2GE Temp Term F 48 F Failsafe minutes 45 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure ...

Page 4: ...1 56 36 72 108 Cycling Anti sweat Heaters NA NA NA NA NA NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 1 20 2 20 3 20 With Energy Efficient Fans 120V 60Hz 0 74 1 24 1 76 Maximum Over Current Protection 120V 20 20 20 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA NA NA Standard Lighting 4 ft 8 ft 12 ft 4 ft 8 ft 12 ft 1 Row Canopy 0 51 1 02 1 54 59 118 177 Optional Lighting 2 Rows Canopy...

Page 5: ... Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Refrigeration Thermostat To Condensing Unit Field Installed 3 4 Dark Blue Defrost Termination Thermostat BROWN BAND Fans BROWN BAND 120V POWE...

Page 6: ...120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS...