background image

2 of 6

CW2GE 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

CL

Front

A

C

1

/

2

(142)

B

Waste Outlet
& Water Seal

Refrigeration Outlet

(127)

(See Note)

Access Area

CW2GE

81 

1

/

2

(2070)

68 

7

/

8

(1749)

Base Rail

1

/

2

(216)

12 

5

/

8

(321)

3

/

8

(35)

7

/

8

(98)

7

(178)

Dimensions shown as inches and (mm).

Convertible Island

05-2003

4 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

1

/

(1226)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum O/S dimension of case back to front 

(includes bumper)

81 

1

/

2

(2070)

81 

1

/

2

(2070)

81 

1

/

2

(2070)

Front of splashguard to O/S edge of front base rail

1

/

(216)

1

/

(216)

1

/

(216)

Front of case to O/S edge of front base rail

12 

5

/

(321)

12 

5

/

(321)

12 

5

/

(321)

Back of case to O/S edge of front base rail

68 

7

/

(1749)

68 

7

/

(1749)

68 

7

/

(1749)

Width of base rail

1

/

(54)

1

/

(54)

1

/

(54)

Stub-up area between front base rail and splashguard

1

/

(184)

1

/

(184)

1

/

(184)

Electrical Service

Note:

Electrical Field Wiring connection point

Center of Electrical service to O/S edge of front base rail

7 (178)

7 (178)

7 (178) 

Right end of case to center of knockout

5 (127)

5 (127)

5 (127)

Length of electrical raceway

46 

5

/

(1184)

46 

5

/

(1184)

46 

5

/

(1184)

Waste Outlet

(B)

LH End of case to the center of waste outlet

10 

1

/

(257)

38 

1

/

(968)

76 

5

/

(1945)

Center of waste outlet to outside of front base rail

7

/

(98)

7

/

(98)

7

/

(98)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

4 (102)

(C)

RH end of case to center of rear waste outlet

10 

1

/

(257)

38 

1

/

(968)

76 

5

/

(1946)

Outside diameter of the drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

Water seal outlet must clear front skid rail.

Refrigeration Outlet

Center of refrigeration outlet to O/S edge of front base rail

3

/

(35)

3

/

(35)

3

/

(35)

RH end of case to center of refrigeration outlet

5

/

(141)

5

/

(141)

5

/

(141)

Summary of Contents for IMPACT CW2-GE

Page 1: ...698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0398558 Standard Non adjustable 2 Defrost Thermostat C 0144732 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures CW2 GE Data Sheet Set P N 0399334B NSF Cert...

Page 2: ...2 1 8 54 2 1 8 54 2 1 8 54 Stub up area between front base rail and splashguard 7 1 4 184 7 1 4 184 7 1 4 184 Electrical Service Note Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 7 178 7 178 7 178 Right end of case to center of knockout 5 127 5 127 5 127 Length of electrical raceway 46 5 8 1184 46 5 8 1184 46 5 8 1184 Waste Outlet B LH End of...

Page 3: ...llel 1480 Conventional 1640 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA CW2GE Frequency hr 6 Defrost Water lb ft day 10 15 based on case configuration and product loading OFFTIME CW2GE Temp Term F 48 F Failsafe minutes 45 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure ...

Page 4: ...1 56 36 72 108 Cycling Anti sweat Heaters NA NA NA NA NA NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 1 20 2 20 3 20 With Energy Efficient Fans 120V 60Hz 0 74 1 24 1 76 Maximum Over Current Protection 120V 20 20 20 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA NA NA Standard Lighting 4 ft 8 ft 12 ft 4 ft 8 ft 12 ft 1 Row Canopy 0 51 1 02 1 54 59 118 177 Optional Lighting 2 Rows Canopy...

Page 5: ... Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Refrigeration Thermostat To Condensing Unit Field Installed 3 4 Dark Blue Defrost Termination Thermostat BROWN BAND Fans BROWN BAND 120V POWE...

Page 6: ...120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS...

Reviews: