3 of 6
P/N 0407200A
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C
O
I
L
D5ELE
D5EE
FAN
46
1
/
2
(1181)
47
1
/
2
(1207)
6
1
/
8
(201)
37
3
/
4
(959)
Refrigeration
Outlet
29
1
/
2
(749)
31
5
/
8
(803)
26
1
/
2
(672)
7
5
/
8
(194
)
33
1
/
2
(851)
19
(483)
7
1
/
2
(191)
81
1
/
8
(2062)
56
1
/
4
(1429)
61
(1549)
5
1
/
2
(139)
30
3
/
8
(772)
22
(559)
Lighted Shelf
(Optional)
84
3
/
8
(2142)
Impact
D5ELE / D5EE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
NOTE:
The bumpers are 4 in. (102 mm) wide. The center of the top bumper is
14
1
/
4
in. (368 mm) from the floor and the center of the lower bumper
is 6
1
/
8
in. (155 mm) from the floor.
Multi-deck, 5 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF
®
) Standard #7 requirements.
REFRIGERATION DATA
Note:
This data is based on store temperature
and humidity that does not exceed 75
°
F and
55% R.H.
D5ELE D5EE
Discharge Air (°F)
32
32
Evaporator (°F)
24
24
Unit Sizing (°F)
22
22
Btu/hr/case*
D5ELE D5EE
Parallel
10,700
10,170
Conventional
11,400
10,830
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
D5ELE D5EE
Frequency (hr)
6
6
Defrost Water (lb/ft/day)
10.5
10.5
(± 15%
based on case configuration and
product loading).
O
FFTIME
D5ELE D5EE
Temp Term (°F)
48
°
48
°
Failsafe (minutes)
35
35
G
AS OR
E
LECTRIC
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5ELE D5EE
CI/CO (Temp °F)
**
17°/ 7°
17°/ 7°
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)
**
Not Recommended
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.)
1 1/2
Liquid Line (in.)
3/8
Suction Line (in.)
7/8
Estimated Charge (lb)***
D5ELE
2.4
D5EE
2.4
***This is an average for all refrigerant
types. Actual refrigerant charge may vary
by approximately half a pound.
Length Added to Lineup by:
Each End/Partition (in.)
1 1/2