background image

3 of 6

P/N 0378429D

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

C

O

I

L

48 

1

/

4

(1429) 

61

(1549)

81 

3

/

8

(2066) 

45 

5

/

8

(1159)

D5H

FAN 

5

 

3

/

4

(146)

27

(686)

3

 

1

/

8

(79)

7

 

1

/

2

(152) 

7

(178) 

46 

1

/

4

 (1174) 

27 

1

/

2

 (699)

30 

1

/

8

(765)

4

 

1

/

4

(108)

29 

1

/

2

 

(749)

4

1

/

2

(114)

38 

5

/

8

 

(981)

10 

3

/

4

(273)

53 

5

/

8

(1360) 

 (102) 

Impact  

D5H

Dairy & Delicatessen

Dimensions shown as in. and (mm).

NOTE:

The bumpers are 4 in. (102 mm) wide. The center of the top
bumper is 22 

1

/

8

in. (562 mm) from the floor and the center of

the lower bumper is 6 

1

/

8

in. (155 mm) from the floor.

Multi-deck, 5 Display Levels

NSF Certification

These merchandisers are manufactured to meet ANSI /National Sanitation

Foundation (NSF

®

) Standard #7 requirements. 

REFRIGERATION DATA

Note:

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

D5H

D5HE

Discharge Air °F

31

32

Evaporator °F

21

24

Unit Sizing °F

19

22

Btu/hr/ft*

D5H

D5HE

L

IT

& U

NLIT

S

HELVES

Parallel

1330

1280

Conventional

1420

1365

H

USSMANN

P

EG

S

HELVES

(D

ELI ONLY

)

Parallel

1450

1400

Conventional

1540

1485

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

Frequency Hrs

6

6

Defrost Water (lb/ft/day)

10.50

(± 15% 

based on case configuration and

product loading).

O

FFTIME

D5H

D5HE

Temp Term °F

48

48

Failsafe Minutes

35

35

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

**

D5H

D5HE

14°F / 4°F

17°F / 7°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)***

D5H

D5HE

8 ft

2.3

2.7

12 ft

3.3

3.9

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

Length Added to Lineup by

Each End (in.)

1

/

2

Each Insulated Partition (in.)

1

/

2

Summary of Contents for IMPACT D5H

Page 1: ... 1 0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0376409 Ballast Electronic 2 lamps 4 D 0376410 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures D5H Data Sheet Set P N 0378429D NSF ...

Page 2: ...pport and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 7 178 7 178 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34 ...

Page 3: ...tu hr ft D5H D5HE LIT UNLIT SHELVES Parallel 1330 1280 Conventional 1420 1365 HUSSMANN PEG SHELVES DELI ONLY Parallel 1450 1400 Conventional 1540 1485 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency Hrs 6 6 Defrost Water lb ft day 10 50 15 based on case configuration and product loading OFFTIME D5H D5HE Temp Term F 48 48 Failsafe Minutes 35 35...

Page 4: ...uit Ampacity With Standard Fans 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 With Export Fan 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail ...

Page 5: ...ctor Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components...

Page 6: ... models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch...

Reviews: