REFRIGERATION DATA
Note:
This data is based on store temperature
and humidity that does not exceed 75
°
F and
55% R.H.
D5L
D5LE
Discharge Air °F
31
32
Evaporator °F
21
24
Unit Sizing °F
19
22
Btu/hr/ft*
D5L
D5LE
L
IT
& U
NLIT
S
HELVES
Parallel
1495
1425
Conventional
1580
1515
H
USSMANN
P
EG
S
HELVES
(D
ELI ONLY
)
Parallel
1615
1545
Conventional
1700
1635
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs
6
6
Defrost Water (lb/ft/day)
10.25
(± 15%
based on case configuration and
product loading).
O
FFTIME
D5L
D5LE
Temp Term °F
48
48
Failsafe Minutes
30
35
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONALCONTROLS
Low Pressure Backup Control
CI/CO
**
D5L
D5LE
14°F / 4°F
17°F / 7°F
Indoor Unit Only, Pressure Defrost
Termination**
48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
7
/
8
Estimated Charge (lb)***
D5L
D5LE
8 ft
2.3
2.7
12 ft
3.3
3.9
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by End or
Insulated Partition (in.)
1
1
/
2
3 of 6
P/N 0378426E
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
D5L
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF
®
) Standard #7 requirements.
4
(102)
C
O
I
L
61
(1549)
81
3
/
8
(2066)
45
5
/
8
(1159)
D5L
FAN
5
3
/
4
(146)
19
(483)
3
1
/
8
(
79
)
56
1
/
4
(1429)
7
1
/
2
(152)
7
(178)
46
1
/
4
(1174)
27
1
/
2
(699)
30
1
/
8
(765)
4
1
/
4
(108)
29
1
/
2
(749)
4
1
/
2
(114
)
38
5
/
8
(981)
2
3
/
4
(70
)
53
5
/
8
(1360)
14
1
/
8
(359)
6
1
/
8
(155)