2 of 6
D5NGE Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Electrical
Waste Outlet
A
(see note)
B
C
D
40
5
/
8
(1030)
27
(688)
27
1
/
2
(699)
4
1
/
2 (114)
25
1
/
2
(648)
33
1
/
8
(841)
40
5
/
8
(1030)
5
1
/
2 (140)
1
3
/
8 (035)
4
(102)
Water Seal
5
5
/
8
(143)
40
5
/
8
(1032)
29
1
/
8
(739)
4
1
/
2 (105)
72
1
/
4 (1835)
Refrigeration
Front
Dimensions shown as in. and (mm).
Narrow Dairy &
Delicatessen
8 ft
12 ft
General
(A)
Case Length (without ends or partitions)
96
3
/
8
(2448)
144
1
/
2
(3670)
Maximum O/S dimension of case back to front
(includes bumper)
40
5
/
8
(1030)
40
5
/
8
(1030)
Back of case to front of splashguard
33 (840)
33 (840)
Back of case to O/S edge of front skid rail
25
1
/
2
(648)
25
1
/
2
(648)
Width of skid rail
4
1
/
2
(114)
4
1
/
2
(114)
RH end of case to outside edge of external support
5
1
/
2
(140)
5
1
/
2
(140)
Distance between edges of external support and center support
40
5
/
8
(1032)
40
5
/
8
(1032)
Distance between edges of center supports
NA
44 (1118)
Stub-up area between front skid rail and splashguard
5
5
/
8
(143)
5
5
/
8
(143)
Electrical Service
(Electrical Field Wiring connection point)
(B)
RH End of case to center of farthest knockout
88
3
/
8
(2245)
136
1
/
2
(3467)
Back of case to center of knockout
29
1
/
8
(739)
29
1
/
8
(739)
Length of electrical raceway
34
5
/
8
(878)
34
5
/
8
(878)
Waste Outlet
(C)
RH End of case to the center of waste outlet
24
1
/
8
(613)
72
1
/
4
(1835)
LH End of case to the center of waste outlet
72
1
/
4
(1835)
72
1
/
4
(1835)
Back O/S of case to center of waste outlet
27 (686)
27 (686)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
Outside diameter of the drip pipe
1
1
/
2
(38)
1
1
/
2
(38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet
27
1
/
2
(699)
27
1
/
2
(699)
(D)
RH end of case to center of refrigeration outlet
9 (230)
9 (230)
04-2003