8 ft
12 ft
General
(A)
Case Length*
96
3
/
8
(2448)
144
1
/
2
(3670)
Maximum O/S dimension of case back to front
53
1
/
8
(1349)
53
1
/
8
(1349)
(Note: Includes bumper and wall)
Back of case to O/S edge of front bumper
48
7
/
8
(1241)
48
7
/
8
(1241)
Back of case to front of splashguard
44 (1118)
44 (1118)
* Each End and Insulated Partition adds 1
1
/
2
in. (38 mm) to the length of the lineup.
Electrical Service
** Electrical Field Wiring Connection Point
Back of case (wall) to center of 4x4x2 Electrical box
7
5
/
8
(195)
7
5
/
8
(195)
(B)
RH End of case to center of 4x4x2 Upper Electrical box
2
1
/
2
(64)
2
1
/
2
(64)
(C)
RH End of case to center of Lower Electrical box
3
1
/
8
(79)
3
1
/
8
(79)
Waste Outlet
(D)
End of case to the center of waste outlet
1
1
/
4
(32)
1
1
/
4
(32)
Outside diameter of the drip pipe
7
/
8
(22)
7
/
8
(22)
Refrigeration Outlet
Back of case (wall) to center of refrigeration outlet
6
3
/
4
(171)
6
3
/
4
(171)
(E)
LH end of case to center of refrigeration outlet
3
1
/
2
(89)
3
1
/
2
(89)
Outside diameter of the liquid line
3
/
8
(10)
3
/
8
(10)
Outside diameter of the suction line
7
/
8
(22)
7
/
8
(22)
D5RRIS
Technical Data Sheet
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D
Front
C
L
Waste
Outlet
Upper Electrical
Box
Upper Refrigeration
Outlet
Cooler Wall
B
D
47
3
/
4
(1214)
53
1
/
8
(1349)
E
6
3
/
4
(171)
Canopy
Bumper
7
5
/
8
(195)
34
1
/
8
(867)
Cart Stop Rail
C
9
7
/
8
(251)
Lower Electrical
Box
A
Engineering
Plan Views
Suspended
Roll-in Rear Load
Dairy
3-2003
Dimensions shown as in. & (mm).
NOTE: When joining D5 models with D5RRI or D5RRIS models, the drain location
for the D5 must be moved forward 2.325 inches (59 mm) to allow fronts to align.