REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75 (

°

F)

and 55% R.H.

E2

M

EAT

D

ELI

Discharge Air (°F)

25

27

Evaporator

(

°F)

18

21

Unit Sizing 

(

°F)

16

19

Btu/hr/ft*

Parallel

945

920

Conventional

1030

1000

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

Frequency (hr)

6

Defrost Water 

8 lb/ft/day

(± 15% 

based on case configuration and

product loading).

O

FFTIME

E2

Temp Term 

(

°F)

48

Failsafe (minutes)

40

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close  48°F – open  33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control  CI/CO

**

E2

Meat

Deli

Temp (°F)

11 / 6

14 / 4

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

E2

4 ft

0.9

6 ft

1.8

8 ft

1.9

12 ft

2.9

***This is an average for all refrigerant types
actual refrigerant charge may vary 
by approximately half a pound.

Length (in.) Added to Lineup by
Each End or Insulated Partition

1

3 of 7

P/N 0453526A

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact 

Elite

E2

Delicatessen

Precut & Packaged Produce

Elite Specialty Merchandiser Multi-deck,  2  Display Levels

Dimensions shown as in. & (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

1

/

2

  

(191)

48 

3

/

4

(1238)

FAN

C

O

I

L

31 

(787)

23 

3

/

4

(603)

17 

1

/

8

(435)

12

(305)

22

(559)

34 

1

/

2

(876)

46 

1

/

2

(1181)

12

(305)

27 

5

/

8

(702)

30 

3

/

4

(781)

E2

1

/

4

(108)

12 

(305)

18 

(457)

Refrigeration
Outlet

See Page 7 for
shelf arrangement.

Summary of Contents for IMPACT Elite E2

Page 1: ...iption Wiring Item LAMPS AND BALLASTS D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtur...

Page 2: ...8 752 29 5 8 752 29 5 8 752 29 5 8 752 D RH End of case to RH end of raceway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of raceway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste...

Page 3: ...e a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is...

Page 4: ...6 0 56 0 84 44 89 89 132 Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 70 1 20 1 20 1 70 With Energy Efficient Fans 120V 60 Hz 0 46 0 72 0 72 0 98 With Export F...

Page 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Page 6: ...ents in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL...

Page 7: ...ions It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case p...

Reviews:

Related manuals for IMPACT Elite E2