background image

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75 (

°

F) and 55% R.H.

E2SP

Meat

Deli

Discharge Air (°F)

25

28

Evaporator

(

°F)

18

21

Unit Sizing 

(

°F)

16

19

Btu/hr/ft* 

E2SP

Parallel

900

890

Conventional

1000

980

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

† 

with refrigerated rear storage, add 300 Btu/hr/ft

DEFROST DATA

E2SP

Frequency (hr)

6

Defrost Water 

8 lb/ft/day

(± 15% 

based on case configuration and product

loading).

O

FFTIME

E2SP

Temp Term 

(

°F)

48

Failsafe (minutes)

40

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close  48°F – open  33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control  CI/CO

**

E2SP

Meat

Deli

Temp (°F)

11 / 6

14 / 4

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

**

48°F

**Use a Temperature Pressure Chart to determine
PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

E2SP

4 ft

0.9

6 ft

1.8

8 ft

1.9

12 ft

2.9

***This is an average for all refrigerant types actual
refrigerant charge may vary by approximately half a
pound.

Length Added to Lineup by Each 
End or Insulated Partition

1 in.

5 of 10

P/N 0453525B

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

C
O

I

L

Refrigeration
Outlet

FAN

COIL

Electrical
Connection
Cavity & Fan

w/Refrigerated

Storage

w/ Non refrigerated

Storage

12

(305)

22

(559)

40 

1

/

4

(1022)

35

(889)

3

/

4  

(248)

12

(305)

19 

1

/

8

(486)

31

(787)

E2SP

31 

1

/

4

(794)

28 

1

/

8

(714)

20

(508)

Standard Curved
Sneeze Guard

53 

3

/

4

(1365)

47

(1194)

59

(1499)

3

/

(121)

63

(1600)

1

/

4

(235)

36

(914)

16

(406)

12

(305)

Impact 

Elite

E2SP

Meat, Delicatessen

Precut & Packaged Produce

Elite Specialty Merchandiser Multi-deck, Prep Top, 2 Display Levels
Optional Rear Storage, Refrigerated or Non refrigerated

Dimensions shown as in. & (mm).

See Page 9 for
shelf arrangement.

Shown with curved sneeze guard
and optional refrigerated and
non-refrigerated rear storage.

Summary of Contents for IMPACT Elite E2SP

Page 1: ...d 2 Rear Storage C 0404551 Cavity Fan Ambient 3 D 0411744 Standard Non adjustable 4 Defrost Thermostat Item Part Description Wiring Item E 0353949 Optional Adjustable 5 Refrigeration Thermostat LAMPS AND BALLASTS F 0466234 Ballast Electronic 2 lamps 6 F 0466235 Ballast Electronic 3 lamps 6 F 0466236 Ballast Electronic 4 lamps 6 G Fluorescent Lamp 7 Replace with like fixtures SHOWN WITH OPTIONAL RE...

Page 2: ...l Field Wiring connection point B Length of electrical raceway 36 1 8 918 26 5 8 676 36 1 8 918 36 1 8 918 RH End of case to center of farthest knockout 11 3 8 289 11 3 8 289 11 3 8 289 11 3 8 289 Back of case to center of end knockout 6 3 8 162 6 3 8 162 6 3 8 162 6 3 8 162 C RH End of case to RH end of raceway 6 1 8 156 6 1 8 156 6 1 8 156 6 1 8 156 Waste Outlet D RH End of case to the center of...

Page 3: ...Deli Temp F 11 6 14 4 Indoor Unit Only Pressure Defrost Termination Temp F 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SP 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added ...

Page 4: ...9 Distance between edges of center supports NA NA NA 44 1118 Distance between edges of external supports 37 940 NA NA NA Stub up area between front skid rail and front panel 5 3 4 146 5 3 4 146 5 3 4 146 5 3 4 146 Electrical Service Electrical Field Wiring connection point B RH End of case to LH end of connection box 42 1 8 1070 42 1 8 1070 42 1 8 1070 91 3 8 2321 E Back of storage to NONREFRIGERA...

Page 5: ...HYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SP 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End or Insulated Partition 1 in 5 of 10 P N 0453525B HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A C O I L Refrigeration ...

Page 6: ...mbient Air Fan 0 26 0 26 0 26 0 26 23 23 23 23 Standard on Optional Refrigerated Rear Storage Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 90 1 60 1 60 2 30 With Rear Refrigerated Storage standard fans 1 96 3 46 3 46 5 56 With Energy Efficient Fans 120V 60 Hz 0 58 0 96 0 96 1 34 With Export Fans 230V 50Hz 0 58 0 96 0 96 1 34 Maximum Over Current Protection ...

Page 7: ...Blue 4 1 2 or 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Optional Refrigerated Rear Storage 1 or 2 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 2 BROWN BAND 4 ft case has 1 Fan 6 ft case has 1 Fan 8 ft case has 2 Fans 12 ft case has 2 Fans 4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans 12 ft case has 3 Fans Cavity Fan Ambient 120V NEUTRAL BROWN BAND 120V POWER Fan 3...

Page 8: ...NING All components must have mechanical ground and the merchandiser must be grounded Connector 6 Connector G 7 7 7 Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G W R G G R R R G G G R BL BL Connector Connector B 4 ft 6 ft 8 ft 12 ft R R BL B...

Page 9: ...G All components must have mechanical ground and the merchandiser must be grounded 120V POWER 120V NEUTRAL R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND 6 BL R R BL BL R 7 7 7 B 4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps 4 ft case has 1 ...

Page 10: ...r stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performance Check with Hussmann engineering before using a different configuration Load Limit 12 in 10 Recommended Angle Shelf Size 18 in 0 Impact Elite E2SP Meat Delicatessen Precut Packaged Produce 10 of 10 E2SP Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044...

Reviews:

Related manuals for IMPACT Elite E2SP