background image

7 of 10

P/N 0453525B

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  120V P

OWER

=  120V N

EUTRAL

Defrost

Termination

Thermostat

Refrigeration

Thermostat

Dark Blue

5

To
Condensing
Unit

}

Light Blue

4

1, 2 or 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

Optional Refrigerated Rear Storage,
1 or 2 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

2

B

ROWN

  B

AND

  4 ft case has 1 Fan
  6 ft case has 1 Fan
  8 ft case has 2 Fans
12 ft case has 2 Fans

  4 ft case has 1 Fan
  6 ft case has 2 Fans
  8 ft case has 2 Fans
12 ft case has 3 Fans

Cavity Fan, Ambient

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fan

3

B

ROWN

  B

AND

  4 ft case has 1 Fan
  6 ft case has 1 Fan
  8 ft case has 1 Fan
12 ft case has 1 Fan

Fan  Wiring

Offtime Defrost

Summary of Contents for IMPACT Elite E2SP

Page 1: ...d 2 Rear Storage C 0404551 Cavity Fan Ambient 3 D 0411744 Standard Non adjustable 4 Defrost Thermostat Item Part Description Wiring Item E 0353949 Optional Adjustable 5 Refrigeration Thermostat LAMPS AND BALLASTS F 0466234 Ballast Electronic 2 lamps 6 F 0466235 Ballast Electronic 3 lamps 6 F 0466236 Ballast Electronic 4 lamps 6 G Fluorescent Lamp 7 Replace with like fixtures SHOWN WITH OPTIONAL RE...

Page 2: ...l Field Wiring connection point B Length of electrical raceway 36 1 8 918 26 5 8 676 36 1 8 918 36 1 8 918 RH End of case to center of farthest knockout 11 3 8 289 11 3 8 289 11 3 8 289 11 3 8 289 Back of case to center of end knockout 6 3 8 162 6 3 8 162 6 3 8 162 6 3 8 162 C RH End of case to RH end of raceway 6 1 8 156 6 1 8 156 6 1 8 156 6 1 8 156 Waste Outlet D RH End of case to the center of...

Page 3: ...Deli Temp F 11 6 14 4 Indoor Unit Only Pressure Defrost Termination Temp F 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SP 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added ...

Page 4: ...9 Distance between edges of center supports NA NA NA 44 1118 Distance between edges of external supports 37 940 NA NA NA Stub up area between front skid rail and front panel 5 3 4 146 5 3 4 146 5 3 4 146 5 3 4 146 Electrical Service Electrical Field Wiring connection point B RH End of case to LH end of connection box 42 1 8 1070 42 1 8 1070 42 1 8 1070 91 3 8 2321 E Back of storage to NONREFRIGERA...

Page 5: ...HYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SP 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End or Insulated Partition 1 in 5 of 10 P N 0453525B HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A C O I L Refrigeration ...

Page 6: ...mbient Air Fan 0 26 0 26 0 26 0 26 23 23 23 23 Standard on Optional Refrigerated Rear Storage Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 90 1 60 1 60 2 30 With Rear Refrigerated Storage standard fans 1 96 3 46 3 46 5 56 With Energy Efficient Fans 120V 60 Hz 0 58 0 96 0 96 1 34 With Export Fans 230V 50Hz 0 58 0 96 0 96 1 34 Maximum Over Current Protection ...

Page 7: ...Blue 4 1 2 or 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Optional Refrigerated Rear Storage 1 or 2 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 2 BROWN BAND 4 ft case has 1 Fan 6 ft case has 1 Fan 8 ft case has 2 Fans 12 ft case has 2 Fans 4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans 12 ft case has 3 Fans Cavity Fan Ambient 120V NEUTRAL BROWN BAND 120V POWER Fan 3...

Page 8: ...NING All components must have mechanical ground and the merchandiser must be grounded Connector 6 Connector G 7 7 7 Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G W R G G R R R G G G R BL BL Connector Connector B 4 ft 6 ft 8 ft 12 ft R R BL B...

Page 9: ...G All components must have mechanical ground and the merchandiser must be grounded 120V POWER 120V NEUTRAL R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND 6 BL R R BL BL R 7 7 7 B 4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps 4 ft case has 1 ...

Page 10: ...r stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performance Check with Hussmann engineering before using a different configuration Load Limit 12 in 10 Recommended Angle Shelf Size 18 in 0 Impact Elite E2SP Meat Delicatessen Precut Packaged Produce 10 of 10 E2SP Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044...

Reviews: