background image

E2SPH

Meat, Delicatessen 

Precut & Packaged 

Produce 

with 2 Hot Wells

4 ft

General

Case Length 

(without ends or partitions)

48 

1

/

8

(1222)

Maximum O/S dimension back to front 

(with bumper)

63 (1600)

Back of case to front of front panel

35 (889)

Back of case to O/S edge of front skid rail

29 

3

/

(756)

Width of skid rail

1

/

(114)

RH end of case to outside edge of external support

3

/

8

(35)

Stub-up area between front skid rail and front panel

3

/

4

(146)

Electrical Service                         

(Electrical Field Wiring connection point)

RH End of case to LH end of connection box

42 

1

/

(1070)

Back of storage to connection box,

center of knockout

11 (279)

Waste Outlet

RH End of case to the center of waste outlet

24 

1

/

(616)

LH End of case to the center of waste outlet

23 

7

/

(606)

Back O/S of case to center of waste outlet

28 

1

/

(714)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

Outside diameter of the drip pipe

1

/

(38)

NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.

Refrigeration Outlet

Back of case to center of refrigeration outlet

31 

1

/

(794)

RH end of case to center of refrigeration outlet

3

/

(213)

2 of 8

E2SPH  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as inches and (mm).

10-2005

23

 7

/

8

(606)

Connection Box
(Field Connection Point)

4 Ft Case

Front

Waste
Outlet

Water
Seal

42

 1

/

8

(1070)

6

 

(152)

Ballast Tray

48

 1

/

8

(1222)

24

 1

/

4

(616)

8

 3

/

(213)

11

(279)

16

(406)

28

 1

/

8

(714)

31

 1

/

4

(794)

47

(1194)

63

(1600)

Summary of Contents for IMPACT Elite E2SPH

Page 1: ...embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0353949 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0466234 Ba...

Page 2: ...center of waste outlet 24 1 4 616 LH End of case to the center of waste outlet 23 7 8 606 Back O S of case to center of waste outlet 28 1 8 714 Water Seal Edge of water seal to center of waste outlet...

Page 3: ...ns PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SPH 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigeran...

Page 4: ...ndard 0 90 120V 50Hz Standard 1 01 230V 60Hz Export 0 53 230V 50Hz Export 0 58 120V 60Hz Energy Efficient 0 58 230V 60Hz Energy Efficient 0 39 Maximum Over Current Protection 120V 20 Maximum Over Curr...

Page 5: ...0 V Power B W G B BL G W BL Shelf Harness Shelf Light Circuits 4 W R G R Shelf Lighting G R 5 Connector Connector B 4 ft case has 1 Fan 4 ft BL Connector G 120V POWER 120V NEUTRAL Field GROUND Case GR...

Page 6: ...TRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND BL R 4 5 R 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B 4 ft case has 1 Lamp BL R 4 5 R 4 ft case...

Page 7: ...at LH or RH Well Marker R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be...

Page 8: ...e two locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides opt...