background image

4 of 8

E2SPH  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact 

Elite

E2SPH

Meat, Delicatessen
Precut & Packaged Produce

Electrical Data

4 ft

Number of Fans — 12W

1

Amperes

Watts

Merchandiser

4 ft

4 ft

Fans

120V

60Hz

Standard

0.70

55

120V

50Hz

Standard

0.81

59

230V

60Hz

Export

0.33

54

230V

50Hz

Export

0.38

57

120V

60Hz

Energy Efficient

0.38

25

230V

60Hz

Energy Efficient

0.19

25

Cycling Anti-sweat Heaters

NA

Minimum Circuit Ampacity

120V

60Hz

Standard

0.90

120V

50Hz

Standard

1.01

230V

60Hz

Export

0.53

230V

50Hz

Export

0.58

120V

60Hz

Energy Efficient

0.58

230V

60Hz

Energy Efficient

0.39

Maximum Over Current Protection (120V)

20

Maximum Over Current Protection (230V)

15

Hot Wells 

208V 

60 Hz

One Hot Well

5.8

1200

240V

60 Hz

One Hot Well

6.7

1600

208V 

60 Hz

Two Hot Wells

11.6

2400

240V

60 Hz

Two Hot Wells

13.4

3200

Standard Lighting

1 Row Canopy

0.51

62

Optional Lighting

1 Row Rail Lights

0.51

62

1 Row Ledge Lights

0.51

62

Optional Shelf Lighting

1 Row of Shelves

0.51

62

2 Rows of Shelves

0.51

62

Optional Overhead Lighting

1 Row of Incandescent Lamps (2 lamps)

1.26

150

1 Row of Heat Lamps (2 lamps)

2.92

350

Summary of Contents for IMPACT Elite E2SPH

Page 1: ...embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0353949 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0466234 Ba...

Page 2: ...center of waste outlet 24 1 4 616 LH End of case to the center of waste outlet 23 7 8 606 Back O S of case to center of waste outlet 28 1 8 714 Water Seal Edge of water seal to center of waste outlet...

Page 3: ...ns PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SPH 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigeran...

Page 4: ...ndard 0 90 120V 50Hz Standard 1 01 230V 60Hz Export 0 53 230V 50Hz Export 0 58 120V 60Hz Energy Efficient 0 58 230V 60Hz Energy Efficient 0 39 Maximum Over Current Protection 120V 20 Maximum Over Curr...

Page 5: ...0 V Power B W G B BL G W BL Shelf Harness Shelf Light Circuits 4 W R G R Shelf Lighting G R 5 Connector Connector B 4 ft case has 1 Fan 4 ft BL Connector G 120V POWER 120V NEUTRAL Field GROUND Case GR...

Page 6: ...TRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND BL R 4 5 R 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B 4 ft case has 1 Lamp BL R 4 5 R 4 ft case...

Page 7: ...at LH or RH Well Marker R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be...

Page 8: ...e two locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides opt...