background image

Optional Lighting:  1 Row Ledge  or  1 Row Rail

Light Circuits

Standard  Lighting  1 Row Canopy

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

=  120V P

OWER

=  120V N

EUTRAL

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

BL

R

4

5

R

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

  4 ft case has 1 Lamp
  

BL

R

4

5

R

  4 ft case has 1 Lamp
  

B

Optional Lighting:  Overhead 75W Incandescent or 175W Heat Lamp

  4 ft case has 2 Lamps
  

Connector

Connector

G

120 V

Power

B

W

G

W

W

B

B

Connector

Connector

Connector

Overhead

Light

Switch

W

G

B

O

RANGE

 

OR

 T

AN

B

AND

6 of 8

E2SPH  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Summary of Contents for IMPACT Elite E2SPH

Page 1: ...embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0353949 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0466234 Ba...

Page 2: ...center of waste outlet 24 1 4 616 LH End of case to the center of waste outlet 23 7 8 606 Back O S of case to center of waste outlet 28 1 8 714 Water Seal Edge of water seal to center of waste outlet...

Page 3: ...ns PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SPH 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigeran...

Page 4: ...ndard 0 90 120V 50Hz Standard 1 01 230V 60Hz Export 0 53 230V 50Hz Export 0 58 120V 60Hz Energy Efficient 0 58 230V 60Hz Energy Efficient 0 39 Maximum Over Current Protection 120V 20 Maximum Over Curr...

Page 5: ...0 V Power B W G B BL G W BL Shelf Harness Shelf Light Circuits 4 W R G R Shelf Lighting G R 5 Connector Connector B 4 ft case has 1 Fan 4 ft BL Connector G 120V POWER 120V NEUTRAL Field GROUND Case GR...

Page 6: ...TRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND BL R 4 5 R 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B 4 ft case has 1 Lamp BL R 4 5 R 4 ft case...

Page 7: ...at LH or RH Well Marker R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be...

Page 8: ...e two locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides opt...