background image

3 of 7

P/N 0475958

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

10 

(254)

15 

(381)

22 

(559)

31 

(787)

Refrigeration
Outlet

FAN

C

O

I

L

E2V

52 

3

/

4

(1340)

25 

3

/

8

(645)

1

/

4

(108)

27 

5

/

8

(702)

30 

3

/

4

(781)

34 

1

/

2

(876)

46 

1

/

2

(1181)

18

(457)

26

(660)

23 

3

/

4

(606)

15 

3

/

4

 

(400)

12

(305)

Impact 

Elite

E2V

Delicatessen

Precut & Packaged Produce

Elite Specialty Merchandiser Multi-deck,  up to 3  Display Levels

Dimensions shown as in. & (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

See Page 7 for
shelf arrangement.

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75 (

°

F)

and 55% R.H.

E2V

M

EAT

D

ELI

Discharge Air (°F)

25

27

Evaporator

(

°F)

18

21

Unit Sizing 

(

°F)

16

19

Btu/hr/ft*

Parallel

945

920

Conventional

1030

1000

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

Frequency (hr)

6

Defrost Water 

8 lb/ft/day

(± 15% 

based on case configuration and

product loading).

O

FFTIME

E2V

Temp Term 

(

°F)

48

Failsafe (minutes)

40

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close  48°F – open  33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control  CI/CO

**

E2V

Meat

Deli

Temp (°F)

11 / 6

14 / 4

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

E2V

4 ft

0.9

6 ft

1.8

8 ft

1.9

12 ft

2.9

***This is an average for all refrigerant types
actual refrigerant charge may vary 
by approximately half a pound.

Length (in.) Added to Lineup by Each
End or Insulated Partition

1

Summary of Contents for IMPACT Elite E2V

Page 1: ...g Item LAMPS AND BALLASTS D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN...

Page 2: ...l 5 3 4 146 5 3 4 146 5 3 4 146 5 3 4 146 Electrical Service Electrical Field Wiring connection point B Length of electrical raceway 18 3 8 467 18 3 8 467 37 940 37 940 C RH End of case to center of f...

Page 3: ...F 18 21 Unit Sizing F 16 19 Btu hr ft Parallel 945 920 Conventional 1030 1000 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency hr 6 Defrost Water...

Page 4: ...Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 70 1 20 1 20 1 70 With Energy Efficient Fans 120V 60 Hz 0 46 0 72 0 72 0 98 With Export Fans 230V 50Hz 0 48 0 76 0...

Page 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Page 6: ...nts in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL...

Page 7: ...locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal...

Reviews: