4 of 8
E3S
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
Elite
E3S
Delicatessen
Precut & Packaged Produce
Electrical Data
4 ft
6 ft
8 ft
12 ft
Number of Fans—7W
1
2
2
3
Number of Fans—7W (Export)
1
2
2
3
(Export: 230V 50 Hz shown)
Amperes
Watts
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
Evaporator Fan
120V
60Hz
Standard
0.50
1.00
1.00
1.50
39
78
78
117
120V
50Hz
Standard
0.55
1.10
1.10
1.65
42
84
84
126
230V
60Hz
Export
0.25
0.50
0.50
0.75
39
78
78
117
230V
50Hz
Export
0.28
0.56
0.56
0.84
42
84
84
126
120V
60Hz
Energy Efficient
0.19
0.38
0.38
0.57
14
28
28
42
230V
60Hz
Energy Efficient
0.10
0.20
0.20
0.30
14
28
28
42
Cycling Anti-sweat Heaters
NA
Minimum Circuit Ampacity
†
120V
60Hz
Standard
0.70
1.20
1.20
1.70
120V
50Hz
Standard
0.75
1.30
1.30
1.85
230V
60Hz
Export
0.45
0.70
0.70
0.95
230V
50Hz
Export
0.48
0.76
0.76
1.04
120V
60Hz
Energy Efficient
0.39
0.58
0.58
0.77
230V
60Hz
Energy Efficient
0.30
0.40
0.40
0.50
Maximum Over Current Protection 120V
20
20
20
20
Maximum Over Current Protection 230V
15
15
15
15
208V Electric Defrost Heaters
NA
Standard Lighting (T-8 fluorescent)
2 Rows of Canopy
0.51
1.01
1.01
1.52
66
122
122
183
Optional Lighting (T-8 fluorescent)
1 Row of Rail Lights
0.51
0.51
0.51
0.76
62
62
62
96
1 Row of Ledge Lights
0.51
0.51
0.51
0.76
62
62
62
96
Optional Shelf Lighting (T-8 fluorescent)
1 Row of Shelves
0.51
0.51
0.51
0.76
62
62
62
96
2 Rows of Shelves
0.51
1.01
1.01
1.52
66
122
122
183
3 Rows of Shelves
0.76
1.53
1.53
2.28
92
184
184
274
120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52