background image

4 of 7

E5  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact 

Elite

E5

Delicatessen
Precut & Packaged Produce

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans — 12W

1

2

2

3

Number of Fans — 12W (Export)

1

2

2

3

(Export: 230V 50 hz shown)

Amperes

Watts

Merchandiser

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Fans

Standard (120V 60Hz)

0.70

1.40

1.40

2.10

50

100

100

150

Energy Efficient (120V 60 Hz)

0.40

0.80

0.80

1.20

22

44

44

66

Export (230V 50Hz)

0.40

0.80

0.80

1.20

57

114

114

172

Cycling Anti-sweat Heaters

NA

Minimu Circuit Ampacity

With Standard Fans (120V 60Hz) 

0.90

1.60

1.60

2.30

With Energy Efficient Fans (120V 60 Hz)

0.60

1.00

1.72

2.48

With Export Fans (230V 50Hz) 

0.60

1.00

1.72

2.48

Maximum Over Current Protection

20

20

20

20

Export (230V 50Hz)

15

15

15

15

Electric Defrost Heaters (208V 1Ph)

NA

Standard Lighting

2 Rows Canopy

0.51

1.02

1.02

1.54

59

118

118

170

Optional Lighting

1 Row Rail Lights

0.51

0.51

0.51

0.77

59

59

59

85

1 Row Ledge Lights

0.51

0.51

0.51

0.77

59

59

59

85

Optional Shelf Lighting

1 Row of Shelves

0.51

0.51

0.51

0.77

29

59

59

85

2 Rows of Shelves

0.51

1.02

1.02

1.54

59

118

118

170

3 Rows of Shelves

1.02

1.53

1.53

2.31

85

177

177

255

4 Rows of Shelves

1.53

2.04

2.04

3.08

118

236

236

340

5 Rows of Shelves

2.04

2.55

2.55

3.85

236

295

295

425

Summary of Contents for IMPACT Elite E5

Page 1: ...ng Item LAMPS AND BALLASTS D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN...

Page 2: ...8 752 29 5 8 752 29 5 8 752 29 5 8 752 D RH End of case to RH end of raceway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of raceway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste...

Page 3: ...erature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E5 4 ft 1 4 6 ft 2 1 8 ft 2 7 12 ft 3 9 This is an aver...

Page 4: ...y With Standard Fans 120V 60Hz 0 90 1 60 1 60 2 30 With Energy Efficient Fans 120V 60 Hz 0 60 1 00 1 72 2 48 With Export Fans 230V 50Hz 0 60 1 00 1 72 2 48 Maximum Over Current Protection 20 20 20 20...

Page 5: ...ed CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case GROUND Connector Connector G Connector Connector Connector Conn...

Page 6: ...ents in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL...

Page 7: ...the five locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides...