background image

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

B1X-GE

Discharge Air (°F)

27

Evaporator (°F)

18

Unit Sizing (°F)

16

Btu/hr/ft

B1X-GE

Parallel

448

Conventional

500

DEFROST DATA

B1X-GE

Frequency (hr)

8

Defrost Water (lb/ft/day)

2.25

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

B1X-GE

Temp Term 

(

°

F

)

43

°

F

Failsafe (minutes)

60

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 43°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

B1X-GE

CI/CO

*

11°F / 1°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to

determine PSIG conversions.

Estimated Charge (lb)**

B1X-GE

4 ft 

0.9

6 ft 

1.2

8 ft 

1.7

12 ft 

2.3

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

3 of 6

P/N 0496237_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

39 

1

/

8

 

(994)

35 

5

/

(905)

3

/

4  

(122)

34 

1

/

8   

(867)

46 

1

/

8

 

(1171)

37 

3

/

(950)

30 

1

/

(765)

Electrical 

Case to Case 

Connections

3 In. 

(77 mm) 

Required 

Air Gap

Refrigeration 
Outlet

23 

1

/

4

 

(591)

34 

3

/

4

 

(883)

11

 

(279)

21 

1

/

(537)

13 

1

/

(334)

7

/

8  

(174)

1

/

(241)

33 

7

/

(860)

1

/

(56)

7

/

(225)

36 

1

/

(921)

FAN

L

RA 

Product Stop

 12

 

(305)

Dimensions shown as inches and (mm).

Single Deck, Wide Footprint, 1 Display Level, Glass Front

Impact  

Excel

B1X-GE

Bulk, High Volume, Meat,

Delicatessen 

Pre-cut and Packaged Produce

B1X-GE

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Reviews: