REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

C2-XE

Discharge Air (°F)

29

Evaporator (°F)

21

Unit Sizing (°F)

19

Btu/hr/ft*

C2-XE

Parallel

1112

Conventional

1190

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

C2-XE

Frequency (hr)

6

Defrost Water (lb/ft/day)

7

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

C2-XE

Temp Term 

(

°

F

)

48

°

F

Failsafe (minutes)

30

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control

C2-XE

CI/CO

**

17°F / 7°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)***

4 ft 

1.3

6 ft 

1.8

8 ft 

2.3

12 ft 

3.3

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

3 of 8

P/N 0398677C

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

1

/

8

 

(155)

(Note:* Optional Accessory Items)

19 

(483)

3

/

4

 

(95)

(Note*)

12 

(305)

(Note*)

(Note*)

(Note*)

(Note*)

18 

(457)

36 

3

/

4

 

(933)

55 

1

/

8

 

(1400)

18 

(457)

30 

1

/

2

 

(775)

23 

(584)

FAN

L

3

/

4

 

(199)

3

/

8

 

(136)

27 

5

/

8

 

(703)

29 

1

/

4

 

(743)

30 

5

/

8

 

(778)

34 

5

/

8

 

(881)

38 

7

/

8

 

(986)

46 

1

/

2

 

(1182)

C2XE

18 

1

/

4

 

(464)

Dimensions shown as inches and (mm).

Multi-deck, 4 Display Levels

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF ®) Standard #7 requirements. 

Impact  

C2-XE

Dairy / Delicatessen 

Precut & Packaged Produce

C2-XE

Summary of Contents for Impact Excel C2X-E

Page 1: ... or replacements for equipment previously sold or shipped Item Part Description Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0311588 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item HEATERS D Canopy Anti Sweat Heater 4 NA 4...

Page 2: ... 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between front skid rail and splashguard 7 3 4 199 7 3 4 199 7 3 4 199 7 3 4 199 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 38 1 4 972 64 3 8 1635 ...

Page 3: ...essure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 3 6 ft 1 8 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0398677C HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A 6 1 8 15...

Page 4: ... 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0 26 0...

Page 5: ...grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G ...

Page 6: ...itch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 5 BL R R BL BL 5 6 6 6 6 6 6 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 5 6 6 R R 6 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMB...

Page 7: ...placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 º 12 in 15 º 14 in or less 30 º 18 in or less 45 º 18 in or less NOTE Shelves placed in the lower positions may be up to 18 in deep when positioned at a 0 º angle Top Eight 8 Shelf Hole Locations 18 in 18 in 14 in 12 in 0 15 30 45 Angle Maximum Shelf Size 18 in...

Page 8: ... lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the canopy by pulling it forward 3 Remove the top panel by lifting it up 4 Service or replace ballasts as required 5 Reassemble items as they were originally installed NOTE Rail lamp ballast is located behind the...

Reviews: